7.1kWh–21.3kWh High-Voltage Stackable LiFePO4 Battery System



Product Overview
Chudu Metal 7.1kWh–21.3kWh High-Voltage Stackable LiFePO4 Battery Systems are designed for residential solar energy storage, self-consumption, backup power and hybrid photovoltaic applications.
The system adopts Lithium Iron Phosphate (LiFePO4 / LFP) battery chemistry and a modular high-voltage architecture. Multiple battery modules can be connected in series and stacked vertically to create different system voltages and storage capacities.
The modular design allows the battery system to be configured according to household electricity consumption, inverter power, photovoltaic system capacity and required backup duration.
An integrated Battery Management System (BMS) monitors battery operation and communicates with a compatible high-voltage hybrid inverter to provide safe, stable and intelligent energy management.
Available Energy Capacity
Typical system energy configurations include:
7.1kWh / 10.6kWh / 14.2kWh / 17.8kWh / 21.3kWh
Actual nominal energy, usable energy, module quantity, system voltage, dimensions and weight depend on the selected configuration.
Current mainstream high-voltage residential battery systems use modular series-connected battery packs to provide different energy and voltage levels. Dyness Tower, for example, uses two to six modules to form 7.10kWh to 21.31kWh systems.
Main Features
High-Voltage Battery Architecture
The system connects multiple battery modules in series to create a high-voltage DC battery platform suitable for compatible residential hybrid and energy storage inverters.
Depending on system configuration, nominal battery voltage can reach several hundred volts DC.
For representative systems in this category, nominal voltage configurations can range from approximately 192V to 576V, while operating voltage can extend from approximately 168V to 657V.
Modular Stackable Design
The modular structure allows battery modules to be vertically stacked to increase storage capacity and system voltage.
This design provides flexible configuration for different residential applications and helps simplify installation and system expansion.
LiFePO4 Battery Chemistry
Lithium Iron Phosphate battery technology provides high thermal stability, long cycle life and stable charge and discharge performance.
LFP chemistry is widely used in residential stationary energy storage because of its safety characteristics and suitability for frequent daily cycling.
Integrated Battery Management System
The integrated BMS manages battery operation and may monitor cell voltage, total system voltage, charge and discharge current, battery temperature, State of Charge, cell balancing, protection status and system communication.
High Depth of Discharge
Depending on battery model and system configuration, recommended Depth of Discharge can typically reach approximately:
90%–95% DoD
Selected current high-voltage residential LFP systems specify up to 95% recommended DoD.
Long Cycle Life
Selected systems can provide:
≥6,000 cycles
under specified testing and operating conditions.
Actual cycle life depends on temperature, Depth of Discharge, charge/discharge rate, battery operating conditions and BMS strategy.
High-Voltage System Efficiency
A high-voltage battery architecture operates at lower current than a low-voltage battery system at the same power level, helping reduce current-related cable losses and supporting higher-power residential energy storage applications.
Intelligent Communication
Depending on the selected battery model, communication interfaces may include:
CAN / RS485 / RS232
Battery communication protocol must be compatible with the selected hybrid or energy storage inverter.
Parallel System Expansion
Selected battery systems support multiple battery towers operating in parallel to increase total storage capacity.
The allowable number of parallel battery systems depends on battery BMS architecture, inverter compatibility and system design. Current commercial systems differ substantially; for example, Dyness Tower supports up to 12 towers in parallel, while GoodWe Lynx Home F supports up to 8 towers.
Indoor & Outdoor Installation Options
Depending on enclosure design, selected systems can provide IP54 or IP55 protection.
Installation location and environmental conditions must follow the requirements of the selected battery model.
Technical Specifications
Parameter |
Specification |
Product Type |
High-Voltage Residential Energy Storage Battery System |
Battery Chemistry |
Lithium Iron Phosphate (LiFePO4 / LFP) |
System Architecture |
Modular / Stackable High-Voltage Battery |
Nominal Energy |
Approx. 7.1kWh – 21.3kWh |
Usable Energy |
Model / Configuration Dependent |
Battery Module Quantity |
Typically 2 – 6 Modules, Depending on Configuration |
Nominal System Voltage |
Approx. 192V – 576V, Depending on Configuration |
Operating Voltage Range |
Approx. 168V – 657V, Depending on Configuration |
Nominal Capacity |
Model Dependent |
Recommended Depth of Discharge |
Typically 90% – 95%, Model Dependent |
Maximum Continuous Charge Power |
Model Dependent |
Maximum Continuous Discharge Power |
Model Dependent |
Maximum Continuous Charge Current |
Model Dependent |
Maximum Continuous Discharge Current |
Model Dependent |
Battery Management System |
Integrated BMS |
Communication |
CAN / RS485 / RS232, Depending on Model |
State of Charge Monitoring |
Supported |
Cell Balancing |
Supported by BMS |
Cycle Life |
≥6,000 Cycles on Selected Models under Specified Conditions |
Parallel Expansion |
Available on Selected Models |
Protection Rating |
Typically IP54 / IP55 on Applicable Models |
Charging Temperature |
Typically Approx. 0°C to 50°C |
Discharging Temperature |
Typically Approx. -10°C to -20°C up to 50°C, Model Dependent |
Relative Humidity |
Up to Approx. 95%, Model Dependent |
Maximum Installation Altitude |
Typically Up to Approx. 2,000m on Applicable Models |
Cooling Method |
Natural / Passive Cooling |
Installation Method |
Floor-Mounted / Stack-Mounted |
Installation Location |
Indoor / Outdoor Depending on IP Rating and Model |
Dimensions |
Configuration Dependent |
Net Weight |
Configuration Dependent |
Compatible Inverter |
Compatible High-Voltage Hybrid / Energy Storage Inverter |
Application |
Residential Solar Storage / Backup Power / Self-Consumption |
Warranty |
According to Selected Model and Warranty Conditions |
The above ranges are consistent with current mainstream high-voltage residential LFP systems. Dyness Tower uses 192–576V nominal system configurations and 168–657V operating ranges, while GoodWe Lynx Home F uses 204.8–512V nominal configurations with an IP55 enclosure.
Note: Technical specifications vary according to battery module quantity, BMS configuration and selected battery model. Final nominal energy, usable energy, nominal voltage, operating voltage, charge/discharge current, power, dimensions, weight, IP rating and communication protocol shall be confirmed according to the selected system configuration.
Typical Battery Configurations
Typical Configuration |
Nominal Energy |
Nominal Voltage |
Usable Energy |
2 Modules |
Approx. 7.10kWh |
Approx. 192V |
Approx. 6.75kWh |
3 Modules |
Approx. 10.66kWh |
Approx. 288V |
Approx. 10.13kWh |
4 Modules |
Approx. 14.21kWh |
Approx. 384V |
Approx. 13.50kWh |
5 Modules |
Approx. 17.76kWh |
Approx. 480V |
Approx. 16.87kWh |
6 Modules |
Approx. 21.31kWh |
Approx. 576V |
Approx. 20.25kWh |
These values represent a typical high-voltage modular battery architecture and should be confirmed against the final supplied battery model before quotation or installation. The reference configuration above corresponds to the current Dyness Tower architecture.
Working Principle
During daytime operation, solar PV modules generate DC electricity and the hybrid inverter converts and manages the photovoltaic energy.
Solar energy can first supply household electrical loads. Excess photovoltaic energy can then be used to charge the high-voltage battery system.
When photovoltaic generation is insufficient or during nighttime operation, stored battery energy is discharged through the compatible hybrid inverter to supply household loads.
When used with a backup-capable inverter, stored battery energy can also provide power to designated loads during utility grid interruptions.
Applications
The system is suitable for residential solar energy storage, home backup power, hybrid photovoltaic systems, residential self-consumption, villas, large residential houses, rural homes, areas with unstable utility grids and residential peak-shaving applications.

High-Voltage vs. Low-Voltage Battery Systems
High-Voltage Battery System
A high-voltage battery system connects multiple battery modules in series to create a battery voltage of several hundred volts DC.
It is commonly used with higher-power residential hybrid inverters, three-phase residential energy storage systems and applications requiring higher charge/discharge power.
Low-Voltage Battery System
Low-voltage residential batteries commonly use approximately 48V / 51.2V battery platforms.
They are widely used with low-voltage hybrid and off-grid solar inverters.
High-voltage and low-voltage battery systems are not directly interchangeable. Battery voltage range, BMS communication protocol and inverter compatibility must be confirmed before installation.
Compatible Inverter Requirements
Before selecting the battery configuration, the inverter's battery voltage range, minimum startup voltage, maximum battery voltage, maximum charge and discharge current, maximum battery power, communication protocol, BMS compatibility, supported battery module quantity and inverter firmware compatibility must be confirmed.
Typical Residential Energy Storage System
A typical high-voltage residential solar energy storage system consists of:
Solar PV Modules + PV Mounting Structure + High-Voltage Hybrid Inverter + High-Voltage Stackable LiFePO4 Battery System + DC Protection + AC Distribution Equipment + Smart Meter + Monitoring System + Household Electrical Loads + Utility Grid
Safety & Protection
Depending on the selected battery system, BMS protection can include cell overvoltage, cell undervoltage, battery overvoltage, battery undervoltage, charge overcurrent, discharge overcurrent, short-circuit, over-temperature, low-temperature charging, cell balancing, communication fault, system alarm and protective shutdown functions.
Communication & Monitoring
Depending on system configuration, the battery and inverter monitoring system may provide State of Charge, system voltage, battery current, charge power, discharge power, cell voltage, battery temperature, operating status, BMS alarms and system fault information.
Communication between the battery system and inverter is typically provided through CAN and/or RS485, with additional interfaces available on selected models.
Installation
The battery system normally uses a floor-mounted stackable architecture.
Battery modules are stacked vertically together with the required battery control unit or BMS controller.
The number of modules determines the total energy capacity, nominal system voltage, system height and overall weight.
Installation must comply with the voltage range, module quantity, ventilation clearance and installation requirements of the selected battery and inverter.
Compliance, Certifications & Transport Documentation
Depending on the selected battery model and destination market, applicable certifications and transportation documents may include:
IEC 62619 / IEC 63056 / IEC 62040 / CE / UKCA / UN38.3 / VDE Requirements / MSDS / Other Applicable Regional Requirements
For example, Dyness Tower currently lists UN38.3, IEC 62619, IEC 63056, IEC 62040, CE-related compliance, UKCA and additional market-specific approvals.
MSDS is transportation and safety documentation rather than a product certification.
Actual certificates and transport documentation must be confirmed according to the selected battery model and destination country.
Information Required for Quotation
- Required energy storage capacity
- Required quantity
- Hybrid inverter brand and model
- Inverter rated power
- Inverter battery voltage range
- Maximum inverter charge/discharge current and power
- Solar PV system capacity
- Estimated daily electricity consumption
- Required backup duration
- Single-phase or three-phase system
- Required parallel expansion capacity
- Installation country
- Indoor or outdoor installation
- Required certifications
Packing & Shipping
Each battery module, BMS/control unit and related accessory is securely packed for international transportation according to the selected system configuration.
Lithium batteries require appropriate packaging, testing and transport documentation according to battery specifications, transport mode and destination country.
Applicable documentation may include UN38.3 test documentation, MSDS and dangerous-goods transport documents.
Chudu Metal
Solar PV Modules, Solar Mounting Components & Solar Product Supplier from China
🌐 Website: www.chudufastener.com
📧 Email: han@hbchudu.com
📱 WhatsApp / Phone: +86 19333039217
description2
Contact Us
- barry@hbchudu.com
- +86 18533933520
-
Hebei Chudu Metal Products Co., Ltd.
Our experts will solve them in no time.


Phone
Facebook
Youtube