Leave Your Message
3kW–12kW Single-Phase Off-Grid Solar Inverter
Off-Grid Solar Inverters

3kW–12kW Single-Phase Off-Grid Solar Inverter

Chudu Metal 3kW–12kW Single-Phase Off-Grid Solar Inverter with MPPT for Residential and Remote Solar Energy Systems

    dd4b8ecb-7879-47a1-ae05-62f4ebd573db
    3daf69fa-d79d-4940-8d53-d8e8fad28a58
    29c6bf62-30cc-4d7a-ba38-0610d6ff961d

    Product Overview


    Chudu Metal 3kW–12kW Single-Phase Off-Grid Solar Inverters are designed for residential, rural and remote-area photovoltaic power systems where reliable electricity is required independently from the utility grid.

    The inverter integrates DC-to-AC power conversion, MPPT solar charging, battery charging and discharging, AC output and intelligent energy management into one compact system.

    Depending on the selected model, the inverter can operate with solar PV modules, battery storage, utility AC input and compatible generators, providing a flexible power solution for homes, villas, farms, remote buildings, shops and other off-grid applications.

    The series covers power ratings from 3kW to 12kW and is available in different PV input, battery and AC output configurations according to project requirements.

    Available Power Range


    Typical available power ratings include:

    3kW / 3.5kW / 4kW / 5kW / 6kW / 8kW / 10kW / 12kW

    Actual available power ratings and electrical configurations depend on the selected inverter model.

    The series is designed primarily for single-phase off-grid solar power and battery energy storage systems.

    Main Features


    Integrated Off-Grid Power Management

    The inverter integrates multiple functions into one unit, which may include:

    • DC/AC inverter
    • MPPT solar charge controller
    • Battery charger
    • Battery discharge management
    • AC input
    • AC bypass
    • Utility charging
    • Generator compatibility
    • Intelligent energy management

    Available functions depend on the selected inverter model.

    MPPT Solar Charging

    Integrated Maximum Power Point Tracking technology continuously tracks the optimum operating point of the PV array to improve solar energy utilization.

    The number of MPPT trackers and PV input channels varies according to inverter model.

    Battery Storage Compatibility

    The inverter can be matched with suitable low-voltage battery energy storage systems.

    Depending on model and communication compatibility, supported batteries may include:

    • Lithium batteries
    • Compatible LiFePO4 battery systems
    • Lead-acid batteries
    • GEL batteries
    • AGM batteries

    For lithium battery systems, communication compatibility between the inverter and battery BMS should be confirmed before system configuration.

    Pure Sine Wave AC Output

    Applicable models provide pure sine wave AC output suitable for common residential and light commercial electrical loads.

    Typical loads can include:

    • Lighting
    • Refrigerators
    • Televisions
    • Computers
    • Fans
    • Air conditioners
    • Water pumps
    • Household appliances
    • Communication equipment

    The total continuous load and starting power must remain within the limits of the selected inverter.

    High Surge Capability

    Selected off-grid inverter models provide temporary surge output above their continuous rated power.

    This makes them suitable for equipment with higher starting current, such as:

    • Water pumps
    • Refrigerators
    • Air conditioners
    • Electric motors
    • Compressors

    Actual surge power and duration depend on the selected inverter model.

    Multiple Energy Sources

    Depending on system configuration, compatible models can manage energy from:

    Solar PV + Battery + Utility AC + Generator

    Operating priority can be configured according to system requirements and available energy sources.

    Utility Backup

    Compatible models can use utility AC power to supply loads and/or recharge the battery when solar generation and battery energy are insufficient.

    Generator Compatibility

    Selected models can operate with a compatible generator as an auxiliary AC power source.

    Generator compatibility, charging control and connection method depend on inverter model and generator specifications.

    Parallel Operation

    Selected models support parallel operation of multiple inverter units for increased system capacity.

    The maximum number of parallel units depends on the inverter model.

    Intelligent Monitoring

    Depending on the selected inverter and communication accessories, monitoring options may include:

    • Wi-Fi
    • RS485
    • GPRS
    • Mobile APP
    • Web monitoring platform

    Users can monitor system operating status, PV generation, battery information, load power and fault alarms.

    Technical Specifications


    Parameter

    Specification

    Product Type

    Off-Grid Solar Inverter / Off-Grid Storage Inverter

    Rated Output Power

    3kW – 12kW

    Phase

    Single-Phase

    Application

    Residential / Rural / Remote Off-Grid Systems

    AC Output Waveform

    Pure Sine Wave on Applicable Models

    Nominal AC Output Voltage

    Typically 220V / 230V / 240V, Model Dependent

    Output Frequency

    50Hz / 60Hz

    Battery System

    Low-Voltage Battery System, Model Dependent

    Battery Type

    Lithium / LiFePO4 / Lead-Acid / GEL / AGM, Subject to Compatibility

    Solar Charge Controller

    Integrated MPPT

    Number of MPPTs

    Model Dependent

    Maximum PV Input Voltage

    Model Dependent

    MPPT Voltage Range

    Model Dependent

    Maximum PV Input Power

    Model Dependent

    AC Input

    Available on Applicable Models

    AC Bypass

    Available on Applicable Models

    Utility Charging

    Available on Applicable Models

    Generator Compatibility

    Available on Selected Models

    Parallel Operation

    Available on Selected Models

    Communication

    RS485 / Wi‑Fi / GPRS Optional

    Monitoring

    APP / Web Platform Optional

    Cooling Method

    Natural Cooling / Intelligent Fan Cooling, Model Dependent

    Installation

    Wall-Mounted or Floor/Wall-Mounted, Depending on Model

    Grid Feed-In

    Not Designed for Grid Export

    Warranty

    According to Selected Model and Project Requirements

    Note: Technical specifications vary between inverter power ratings and product architectures. Final PV voltage, MPPT range, battery voltage, charging current, AC input and output parameters must be confirmed according to the selected inverter model.

    Working Principle


    During daytime operation, solar PV modules generate DC electricity.

    The built-in MPPT solar charge controller manages the photovoltaic energy and continuously optimizes the operating point of the PV array.

    Solar power can be used to supply connected electrical loads, while excess solar energy can be used to charge the battery.

    When solar generation is insufficient, stored battery energy is converted into AC electricity to continue supplying the loads.

    Depending on the selected inverter and operating mode, utility AC power or a compatible generator may also supply the loads or charge the battery when required.

    Unlike a standard grid-tied inverter, an off-grid inverter is designed to establish and maintain an independent AC power supply for connected loads and is not intended to export electricity to the public utility grid.

    Typical Operating Modes


    Depending on the selected inverter model, available operating priorities may include:

    Solar Priority

    Solar PV power supplies the loads first, while excess solar energy charges the battery.

    Solar + Battery

    Solar PV and battery storage work together to supply the connected loads.

    Utility Backup

    Utility AC power provides backup supply when solar generation and battery energy are insufficient.

    Generator Backup

    A compatible generator can provide auxiliary power in remote locations or during extended periods of insufficient solar generation.

    Battery Priority

    Battery energy can be prioritized according to system settings and operating requirements.

    Available operating modes depend on the selected inverter model.

    Applications

    The 3kW–12kW Single-Phase Off-Grid Solar Inverter is suitable for:

    • Residential off-grid solar systems
    • Rural homes
    • Villas
    • Farms
    • Remote houses
    • Cabins
    • Small shops
    • Agricultural facilities
    • Remote construction sites
    • Telecommunications facilities
    • Areas without utility grid access
    • Areas with unstable utility power
    • Solar backup power systems
    38a5e4ea-7250-4555-bc72-efc485

    Typical Power Selection


    Lower-power models such as:

    3kW / 3.5kW / 4kW / 5kW

    are commonly suitable for smaller residential systems and basic household electrical loads.

    Medium and higher-power models such as:

    6kW / 8kW / 10kW / 12kW

    are suitable for larger homes, villas, farms and applications with higher simultaneous electrical loads.

    The correct inverter capacity should be selected according to:

    • Maximum simultaneous load
    • Starting power of motors and appliances
    • Daily electricity consumption
    • Solar PV array capacity
    • Battery capacity
    • Required backup duration

    Compatible Solar PV Modules


    The inverter can be matched with mainstream photovoltaic module technologies, including:

    • Monocrystalline solar modules
    • PERC solar modules
    • N-Type TOPCon solar modules
    • Bifacial solar modules
    • High-power PV modules

    PV string design must comply with the selected inverter's:

    • Maximum PV open-circuit voltage
    • MPPT operating voltage range
    • Maximum PV input current
    • Maximum PV short-circuit current
    • Maximum allowable PV input power

    Battery Compatibility


    Compatible battery configurations may include:

    Lithium Battery
    LiFePO4 Battery
    Lead-Acid Battery
    GEL Battery
    AGM Battery

    For lithium and LiFePO4 systems, communication protocol and BMS compatibility should be confirmed before installation.

    Battery voltage and capacity should be selected according to inverter requirements, electrical loads, daily energy consumption and required backup time.

    Typical Off-Grid Solar System Configuration


    A typical off-grid photovoltaic power system consists of:

    **Solar PV Modules

    • PV Mounting Structure
    • Solar DC Cables & Connectors
    • DC Protection
    • Off-Grid Solar Inverter
    • Battery Energy Storage System
    • AC Distribution Equipment
    • Electrical Loads**

    Optional auxiliary power sources may include:

    Utility AC and/or Generator

    depending on local installation conditions and inverter configuration.

    Off-Grid Inverter vs. Grid-Tied Inverter


    Off-Grid Solar Inverter

    An off-grid inverter is designed to create an independent AC power supply for local electrical loads using solar PV and battery storage.

    It can operate without connection to the public utility grid.

    Battery storage is normally an important part of an off-grid solar system.

    Grid-Tied Solar Inverter

    A grid-tied inverter operates together with the public utility grid.

    It converts solar DC electricity into grid-synchronized AC electricity and normally stops supplying power during a utility outage unless the system includes a separate backup function.

    For areas without reliable utility power, an off-grid inverter or suitable hybrid energy storage system should be selected.

    Transformerless & Low-Frequency Transformer Options


    Different inverter architectures are available within the 3kW–12kW off-grid power range.

    Transformerless Models

    Transformerless off-grid inverters generally offer:

    • Compact size
    • Lower weight
    • High conversion efficiency
    • Flexible residential installation

    Low-Frequency Transformer Models

    Selected higher-power off-grid inverters use built-in low-frequency transformers.

    These models can provide strong surge capability and are suitable for demanding inductive loads such as:

    • Water pumps
    • Motors
    • Compressors
    • Other high-starting-current equipment

    The appropriate inverter architecture should be selected according to load type and project requirements.

    Protection Functions


    Depending on the selected inverter model, protection functions may include:

    • PV reverse polarity protection
    • Battery reverse polarity protection
    • Battery overvoltage protection
    • Battery undervoltage protection
    • Output overload protection
    • Output short-circuit protection
    • Over-temperature protection
    • AC input protection
    • Surge protection
    • Intelligent fan control
    • Battery charging protection

    Actual protection functions depend on the selected inverter model.

    Monitoring & Communication


    Depending on the selected inverter model, protection functions may include:

    • PV reverse polarity protection
    • Battery reverse polarity protection
    • Battery overvoltage protection
    • Battery undervoltage protection
    • Output overload protection
    • Output short-circuit protection
    • Over-temperature protection
    • AC input protection
    • Surge protection
    • Intelligent fan control
    • Battery charging protection

    Actual protection functions depend on the selected inverter model.

    Compliance & Safety Requirements


    Depending on the selected inverter model and destination market, available products may comply with applicable safety and electromagnetic compatibility requirements such as:

    IEC / EN 62109
    CE Requirements
    EMC Requirements
    LVD Requirements
    Other Applicable Regional Safety Standards

    Actual certificates and compliance documents must be confirmed according to the selected inverter model and destination country.

    Information Required for Quotation


    To recommend a suitable off-grid inverter, please provide:

    1. Required inverter power
    2. Maximum simultaneous electrical load
    3. Appliances or equipment with high starting current
    4. Estimated daily electricity consumption
    5. Solar panel wattage and quantity
    6. Battery type
    7. Required battery capacity
    8. Required backup time
    9. Local AC voltage and frequency
    10. Whether utility AC backup is available
    11. Whether generator operation is required
    12. Installation country
    13. Required quantity

    Packing & Shipping


    Each inverter is securely packed for international transportation.

    Packing and transportation methods can be arranged according to inverter model, order quantity and destination.

    Available shipping methods include:

    • Sea freight
    • Air freight
    • Express delivery where suitable
    • LCL shipment
    • FCL shipment
    • Door-to-door logistics where available

    Chudu Metal

    Solar PV Modules, Solar Mounting Components & Solar Product Supplier from China
    🌐 Website:  www.chudufastener.com
    📧 Email:  han@hbchudu.com
    📱 WhatsApp / Phone: +86 19333039217

    description2

    Contact Us

    Our experts will solve them in no time.