30kW–60kW Three-Phase High-Voltage C&I Hybrid Solar Inverter



Product Overview
Chudu Metal supplies 30kW–60kW three-phase high-voltage hybrid solar inverters for Commercial & Industrial (C&I) photovoltaic and battery energy storage systems.
Typical available power classes include:
30kW / 40kW / 50kW / 60kW
These high-power hybrid inverters integrate photovoltaic power conversion, high-voltage battery charge and discharge control, grid interaction, load management and energy management functions into one system.
Depending on the selected inverter model and project configuration, available functions may include:
- Solar PV power conversion
- High-voltage battery energy storage
- Grid-connected operation
- Backup / off-grid operation
- Peak shaving
- Demand management
- Time-of-use energy management
- Self-consumption optimization
- Export power limitation
- Generator integration
- AC coupling
- Multi-inverter parallel operation
- Three-phase unbalanced load support
- Remote monitoring and energy management
This inverter class is suitable for factories, warehouses, commercial buildings, industrial facilities, agricultural projects, EV charging stations and other C&I applications requiring both photovoltaic generation and energy storage.
Available Power Classes
Rated Power |
Typical Application |
30kW |
Small Commercial / Workshop / Agricultural Project |
40kW |
Commercial & Industrial |
50kW |
Commercial & Industrial |
60kW |
Medium C&I / Industrial Energy Storage |
Exact rated power, PV input configuration and battery architecture depend on the selected inverter model.
Main Features
Three-Phase High-Voltage C&I Architecture
The inverter is designed for three-phase Commercial & Industrial photovoltaic and energy storage systems.
High-voltage battery architecture allows higher system power to be transferred at relatively lower DC current compared with low-voltage battery systems.
This is especially useful for:
- Higher-power C&I installations
- Longer-duration battery systems
- High daily energy consumption
- Peak-demand control
- Large rooftop PV projects
Current products in the 30–60kW class use different battery architectures, ranging from approximately 160V to 1000VDC depending on the platform. GoodWe's 40/50kW platform uses 200–800V, while current 60kW Deye platforms extend to 160–1000V.
High-Voltage LiFePO4 Battery Compatibility
These inverters are designed for compatible high-voltage lithium battery systems, particularly LiFePO4 energy storage batteries.
Typical compatible battery formats include:
- High-Voltage Rack-Mounted LiFePO4 Battery Systems
- High-Voltage Battery Cabinets
- Modular C&I Battery Systems
- Outdoor C&I Battery Cabinets
- High-Voltage Stackable Battery Systems
Battery compatibility must be verified according to:
- Battery voltage range
- Nominal battery voltage
- Maximum charge current
- Maximum discharge current
- Number of battery inputs
- Battery BMS protocol
- CAN / RS485 communication
- Battery firmware
- Inverter firmware
Matching only the voltage is not sufficient to guarantee battery compatibility.
Flexible Battery Input Architecture
Different 30kW–60kW inverter platforms use different battery input designs.
Single Battery Input Architecture
Selected 40kW–50kW inverter platforms may use:
Battery Voltage Range: Approx. 200–800VDC
Maximum Continuous Charge Current: Approx. 100A
Maximum Continuous Discharge Current: Approx. 100A
This architecture is used by current GoodWe 40/50kW high-voltage hybrid products.
Dual Battery Input Architecture
Other C&I platforms use two independently controlled high-voltage battery inputs.
Representative configurations include:
70A + 70A
or
80A + 80A
maximum charging/discharging current, depending on model.
Current Solis 30–50kW systems support up to 70A+70A, while current Deye 60kW systems use dual 80A battery inputs.
This is why the website should not state one fixed battery current for every 30–60kW model.
Multiple MPPT Inputs
Depending on inverter power and internal architecture, typical products may provide:
3-6 Independent MPPTs
Representative configurations include:
- 30kW: Typically 3–4 MPPTs
- 40kW: Typically 3–4 MPPTs
- 50kW: Typically 4 MPPTs
- 60kW: Up to 6 MPPTs on Selected Models
Multiple MPPT trackers allow the inverter to manage PV arrays installed with:
- Different roof orientations
- Different tilt angles
- Partial shading
- Multiple roof sections
- Different string groups
Current GoodWe 40/50kW platforms use 3/4 MPPTs, Solis 30–50kW uses up to four MPPTs, while current Deye 60kW products use six MPPTs.
High-Current Solar Module Compatibility
Modern N-Type TOPCon modules can have relatively high operating and short-circuit current.
Depending on inverter architecture, typical C&I hybrid inverters may support approximately:
20–21A per PV string
with approximately:
36–42A operating current per MPPT
on applicable dual-string MPPT platforms.
Maximum short-circuit current per MPPT may reach approximately:
42–55A or higher depending on model
For example, current GoodWe C&I hybrid models provide up to 42A on selected MPPTs, while Solis specifies up to 20A string current and current Deye 60kW products use 36A operating current per MPPT.
The exact PV module current must always be checked against the selected inverter.

PV Oversizing Capability
Selected C&I hybrid inverter models allow PV array capacity to exceed nominal inverter AC output capacity.
Depending on model, the DC PV array may be designed above the inverter's rated AC power to improve annual solar energy utilization.
For example, current GoodWe 40/50kW platforms support substantial DC oversizing and specify up to 150% DC oversizing in product literature.
Actual permissible PV oversizing depends on:
- Maximum PV input power
- Maximum input voltage
- MPPT operating current
- String configuration
- Local climate
- Local grid requirements
- DC/AC design ratio
Backup Power Function
Selected 30kW–60kW hybrid inverters can provide backup or off-grid power.
Depending on model, backup functions may include:
- Automatic grid-to-backup transfer
- Three-phase backup output
- High temporary overload capability
- Battery-powered backup
- PV + battery backup
- Generator-assisted backup
- Unbalanced three-phase loads
Some systems require an external STS – Static Transfer Switch or approved switching equipment to enable full backup operation.
For example, GoodWe's 40/50kW platform uses an STS box for UPS-level switching, while Solis offers backup switching below 10ms on applicable 30–50kW systems.
Therefore, backup capability should always be confirmed according to the exact model and system design.
Peak Shaving
C&I hybrid inverters can work with battery storage to reduce utility-grid demand during periods of high load.
Typical operating strategy:
Low Site Demand → PV / Grid Charges Battery
High Site Demand → Battery + PV Supply Loads
This can help reduce:
- Maximum grid demand
- Peak electricity consumption
- Demand charges
- Grid capacity pressure
Actual savings depend on local electricity tariff structure and energy management strategy.
Time-of-Use Energy Management
Where electricity prices vary by time period, the inverter and battery system can operate according to scheduled charging and discharging periods.
Typical strategy:
Low-Tariff Period → Battery Charging
High-Tariff Period → Battery Discharging
This function is commonly used in commercial and industrial energy storage systems for electricity cost optimization.
Generator Integration
Generator Integration
Selected C&I hybrid inverter models support diesel or other generator integration.
Functions may include:
- Generator power input
- Generator charging of battery
- Automatic generator start / stop
- PV + battery + generator operation
- Generator-assisted backup
- Peak shaving with generator
Current GoodWe and Solis C&I hybrid platforms include generator integration options.
Exact generator interface and control logic depend on the inverter model.
AC Coupling
Selected models support AC coupling.
This allows an energy storage system to be added to an existing PV installation without completely replacing the existing grid-connected solar inverter.
Typical retrofit configuration:
Existing PV Inverter + AC Bus + Hybrid Inverter + Battery
AC coupling capability should be confirmed before system design.
Parallel Operation
Selected 30kW–50kW hybrid inverter models support multiple units operating in parallel.
Parallel operation can provide:
- Higher total system power
- Easier system expansion
- Larger C&I energy storage capacity
- Redundancy
- Flexible project design
For example, Solis 30–50kW platforms support multiple parallel units, and Deye high-power hybrid platforms support multi-unit parallel operation.
Maximum parallel quantity depends on model, firmware, communication design and external switching equipment.
Reference Technical Specifications
Parameter |
Typical Specification |
Product Type |
Three-Phase High-Voltage C&I Hybrid Solar Inverter |
Rated AC Power |
30kW - 60kW |
Typical Power Options |
30 / 40 / 50 / 60kW |
Phase |
Three-Phase |
Battery Type |
High-Voltage Lithium / LiFePO4 |
Battery Voltage Range |
Approx. 160/200V - 800/1000VDC, Model Dependent |
Number of Battery Inputs |
1 - 2, Model Dependent |
Battery Charge / Discharge Current |
Up to Approx. 100A on Selected Single-Input Models; Approx. 70A+70A or 80A+80A on Selected Dual-Input Models |
Maximum PV Input Voltage |
Typically Up to 1000VDC |
MPPT Voltage Range |
Approx. 150/165V - 850VDC, Model Dependent |
PV Start-Up Voltage |
Approx. 180 - 200VDC |
Number of MPPTs |
Typically 3 - 6 |
Maximum Operating Current per MPPT |
Approx. 36 - 42A on Applicable Platforms |
Maximum PV String Current |
Approx. 20 - 21A per String on Applicable Models |
Maximum Short-Circuit Current per MPPT |
Approx. 42 - 55A or Higher, Model Dependent |
Rated AC Voltage |
380V / 400V Three-Phase |
AC Connection |
3L + N + PE on Applicable Models |
Grid Frequency |
50Hz / 60Hz |
Power Factor |
Adjustable, Model Dependent |
THDi |
Typically <3% at Rated Power on Applicable Models |
Maximum Efficiency |
Typically Approx. 98% or Higher, Model Dependent |
Backup Output |
Available on Applicable Models |
Generator Support |
Available on Selected Models |
AC Coupling |
Available on Selected Models |
Parallel Operation |
Available on Selected Models |
Unbalanced Output |
Available on Applicable Models |
Communication |
CAN / RS485 / Ethernet / Wi-Fi / 4G, Model Dependent |
Cooling |
Intelligent Fan / Forced Air Cooling |
Protection Rating |
Typically IP65 / IP66 |
Operating Temperature |
Typically Approx. -35° C / -40° C to +60° C |
Installation |
Indoor / Outdoor |
Mounting |
Wall-Mounted / Floor or System Configuration Dependent |
These figures represent a range of current C&I high-voltage hybrid inverter architectures rather than one single fixed inverter platform.
Reference Configurations by Power Class
30kW Class
Typical characteristics may include:
- Three-phase AC output
- High-voltage battery
- 3–4 MPPTs
- Multiple PV strings
- Peak shaving
- Backup output
- Generator support
- Parallel operation
40kW Class
Typical characteristics may include:
- Approx. 200–800V battery platform on selected models
- 3–4 MPPTs
- Up to approximately 100A battery current on selected platforms
- 1000V maximum PV input
- C&I backup capability
- Generator integration
50kW Class
Typical characteristics may include:
- 3–4 MPPTs
- Single or dual battery inputs
- Up to approximately 100A single-port architecture or approximately 70A+70A dual-port architecture
- High-power C&I PV compatibility
- Parallel operation
60kW Class
Selected newer high-power platforms may provide:
- Approx. 160–1000V high-voltage battery range
- Dual battery inputs
- Up to approximately 80A+80A charge/discharge current
- Up to 6 MPPTs
- 1000V maximum PV input
- Multi-unit parallel operation
Current Deye 60kW C&I hybrid products use this type of architecture.
Reference PV Input Parameters
Parameter |
Typical Range |
Maximum PV Input Voltage |
Up to Approx. 1000VDC |
Start-Up Voltage |
Approx. 180 - 200VDC |
MPPT Voltage Range |
Approx. 150/165 - 850VDC |
Rated PV Voltage |
Approx. 600 - 650VDC, Model Dependent |
Number of MPPTs |
Approx. 3 - 6 |
Strings per MPPT |
1 - 2, Model Dependent |
Typical String Current |
Up to Approx. 20 - 21A per String |
Operating Current per MPPT |
Approx. 36 - 42A on Applicable Models |
Short-Circuit Current per MPPT |
Approx. 42 - 55A or Higher, Model Dependent |
Reference Battery Parameters
Parameter |
Typical Specification |
Battery Chemistry |
Lithium / LiFePO4 |
Battery Architecture |
High-Voltage |
Battery Voltage |
Approx. 160/200V - 800/1000VDC |
Battery Inputs |
1 - 2 |
Single-Port Current |
Up to Approx. 100A on Applicable Models |
Dual-Port Current |
Approx. 70A+70A or 80A+80A on Applicable Models |
Communication |
CAN / RS485 |
Charging Strategy |
BMS-Controlled / Self-Adaptive on Applicable Models |
Final battery compatibility must be confirmed against the inverter manufacturer's approved battery list.
Reference AC Parameters
Parameter |
Typical Specification |
Rated Output Power |
30kW - 60kW |
AC Phase |
Three-Phase |
Rated AC Voltage |
380V / 400V |
Grid Connection |
3L + N + PE on Applicable Models |
Frequency |
50Hz / 60Hz |
Power Factor |
Adjustable |
Output THDi |
Typically <3% |
Maximum Efficiency |
Approx. 98%+ |
Backup Output |
Model Dependent |
Typical System Configuration
A typical C&I hybrid energy storage system may include:
**Solar PV Modules
+ 30kW–60kW Three-Phase High-Voltage Hybrid Inverter
- High-Voltage LiFePO4 Battery System
- EMS / Energy Management Controller
- Smart Meter / CT
- Utility Grid
- AC Distribution Cabinet
- Commercial / Industrial Loads**
Optional equipment may include:
- STS
- Generator
- EV Charger
- Additional Hybrid Inverters
- Existing Grid-Tied PV Inverter
- External EMS
- Remote Monitoring Gateway
Typical Working Principle
During High Solar Generation
PV electricity supplies onsite loads first.
Excess solar power can be used to:
Charge Battery → Export to Grid, if permitted
During Low Solar Generation
The system can supply loads using:
PV + Battery
If additional power is required:
Grid + PV + Battery → Loads
During Peak Demand
Battery energy can be discharged to reduce power purchased from the utility grid.
PV + Battery → Loads
This helps reduce peak grid demand.
During Low-Tariff Periods
Where time-of-use tariffs apply:
Grid / PV → Battery Charging
Stored energy can then be discharged during higher-price periods.
During Grid Failure
When the selected inverter and system are configured for backup:
PV + Battery → Backup Loads
An STS or other approved transfer device may be required depending on inverter architecture.
C&I Battery Compatibility
This inverter class is suitable for use with compatible products such as:
- 20kWh–60kWh High-Voltage Rack-Mounted LiFePO4 Battery Systems
- 100kWh–215kWh High-Voltage LFP Battery Cabinets
- Modular High-Voltage Commercial Battery Systems
- Outdoor C&I Battery Cabinets
For larger battery systems, the following must be checked:
- Battery nominal voltage
- Operating voltage range
- Battery power
- Maximum charge current
- Maximum discharge current
- Battery capacity
- BMS protocol
- Number of parallel battery cabinets
- Battery-to-inverter communication
Solar Module Compatibility
The inverter can be used with current high-efficiency PV modules including:
- N-Type TOPCon Solar Modules
- Bifacial Dual-Glass Modules
- Monofacial Modules
- 500W+ High-Power Modules
- 600W+ C&I Modules
- 700W-Class Modules on Compatible MPPT Designs
Before connecting modules, calculate:
- Module VOC
- Module VMP
- Module ISC
- Module IMP
- Maximum string voltage
- Number of modules per string
- Strings per MPPT
- MPPT input current
- MPPT short-circuit current
- Minimum ambient temperature
High module wattage alone does not determine compatibility.
Energy Management Functions
Depending on the selected inverter and EMS, available operating modes may include:
- Self-Consumption Mode
- Peak Shaving Mode
- Time-of-Use Mode
- Backup Power Mode
- Battery Reserve Mode
- Zero Export Mode
- Export Limitation
- Generator Mode
- Scheduled Charging
- Scheduled Discharging
- Remote Energy Management
Protection Functions
Depending on model, integrated protection may include:
- PV Reverse Polarity Protection
- Battery Reverse Polarity Protection
- DC Overvoltage Protection
- AC Overvoltage Protection
- AC Overcurrent Protection
- Short-Circuit Protection
- Anti-Islanding Protection
- Residual Current Monitoring
- Insulation Resistance Monitoring
- Over-Temperature Protection
- DC Switch
- DC Surge Protection
- AC Surge Protection
- AFCI on Selected Models
- Emergency Shutdown / Remote Shutdown on Selected Models
Exact protection configuration must be confirmed using the selected inverter datasheet.
Monitoring & Communication
Available communication interfaces may include:
- CAN
- RS485
- Ethernet / LAN
- Wi-Fi
- 4G
- Bluetooth
- Modbus
- Cloud Monitoring
- Mobile APP
- Web Portal
Typical monitored information includes:
- PV generation
- PV voltage
- PV current
- Battery State of Charge
- Battery voltage
- Battery current
- Battery power
- Grid import
- Grid export
- Load demand
- Backup load
- Daily energy
- Historical energy
- System alarms
- Device status
Environmental Specifications
Environmental Specifications
Typical C&I hybrid inverter specifications include:
Protection Rating: IP65 / IP66
Installation: Indoor or Outdoor
Operating Temperature: Approx. -35°C / -40°C to +60°C
Cooling: Intelligent Fan / Forced Air Cooling
Maximum Operating Altitude: Model Dependent; Derating May Apply at High Altitude
Relative Humidity: Model Dependent
GoodWe's current 40/50kW system, for example, uses IP66 protection and smart fan cooling.
Typical Applications
30kW–60kW three-phase high-voltage C&I hybrid solar inverters are suitable for:
- Manufacturing Plants
- Factories
- Warehouses
- Industrial Workshops
- Commercial Buildings
- Shopping Centers
- Office Buildings
- Hotels
- Agricultural Facilities
- Farms
- Logistics Centers
- EV Charging Stations
- Solar Carports
- PV + Energy Storage Systems
- Peak-Shaving Projects
- Backup Power Systems
- Microgrids
- Distributed C&I Solar Projects
Compliance & Certification
Depending on brand, exact inverter model and destination market, applicable standards and documentation may include:
- IEC / EN 62109-1
- IEC / EN 62109-2
- IEC / EN 62477-1
- IEC 62116
- IEC 61727
- IEC / EN 61000 Series
- EN 50549
- VDE-AR-N 4105 / Applicable German Grid Standards
- G99 / Applicable UK Grid Standards
- NRS 097
- CE Documentation
- Country-Specific Grid Certifications
Current Solis C&I hybrid products, for example, list IEC/EN 62109, IEC/EN 62477 and IEC/EN 61000 family compliance documentation.
Certification should always be verified according to the exact model + destination country + local grid requirements.
Information Required for Quotation
Please provide:
- Required Power: 30kW / 40kW / 50kW / 60kW
- Destination Country
- Destination Port
- Grid Voltage
- Grid Frequency
- PV System Capacity
- Solar Module Wattage
- Solar Module VOC / VMP / ISC / IMP
- Required Battery Capacity
- Battery Brand and Model, if already selected
- Battery Voltage Range
- Required Charge / Discharge Power
- Peak Load
- Daily Electricity Consumption
- Required Backup Load
- Required Backup Time
- Whether Generator Integration Is Required
- Whether AC Coupling Is Required
- Whether Parallel Operation Is Required
- Required Communication Interface
- Required Grid Certification
- Required Quantity
- EXW / FOB / CIF Requirement
If the battery and inverter have not yet been selected, project load data, PV capacity and destination-country information can be provided so that a suitable configuration can be recommended.
Packing & Shipping
The inverter is normally packed individually with protective carton packaging and internal protective material.
Typical package contents may include:
- C&I Hybrid Inverter
- Mounting Accessories
- PV Connectors
- Battery Connectors
- Communication Accessories
- Meter / CT Accessories, Model Dependent
- Installation Hardware
- User Manual
Exact dimensions, net weight, gross weight and pallet quantity depend on the selected inverter model.
Trade Terms
EXW / FOB / CIF
Please contact us for:
- Current Stock
- Latest Price
- Available Brands
- Exact Model Numbers
- Official Datasheets
- Battery Compatibility Information
- Grid Certification Documents
- Packing Information
- Container Loading Information
- Shipping Quotation
Chudu Metal
Solar PV Modules, Solar Inverters, Energy Storage Batteries & Solar Mounting Components Supplier from China
🌐 Website: www.chudufastener.com
📧 Email: han@hbchudu.com
📱 WhatsApp / Phone: +86 19333039217
description2
Contact Us
- barry@hbchudu.com
- +86 18533933520
-
Hebei Chudu Metal Products Co., Ltd.
Our experts will solve them in no time.


Phone
Facebook
Youtube