Leave Your Message
30kW–60kW Three-Phase High-Voltage C&I Hybrid Solar Inverter
Hybrid Solar Inverters

30kW–60kW Three-Phase High-Voltage C&I Hybrid Solar Inverter

Chudu Metal 30kW–60kW Three-Phase High-Voltage C&I Hybrid Solar Inverter for Commercial & Industrial Energy Storage Systems

    a35287ca-0ed6-4146-bbdf-558d9bdd3f01
    主图
    75b3b076-8174-41ec-b7e8-ae0d1e38b988

    Product Overview


    Chudu Metal supplies 30kW–60kW three-phase high-voltage hybrid solar inverters for Commercial & Industrial (C&I) photovoltaic and battery energy storage systems.

    Typical available power classes include:

    30kW / 40kW / 50kW / 60kW

    These high-power hybrid inverters integrate photovoltaic power conversion, high-voltage battery charge and discharge control, grid interaction, load management and energy management functions into one system.

    Depending on the selected inverter model and project configuration, available functions may include:

    • Solar PV power conversion
    • High-voltage battery energy storage
    • Grid-connected operation
    • Backup / off-grid operation
    • Peak shaving
    • Demand management
    • Time-of-use energy management
    • Self-consumption optimization
    • Export power limitation
    • Generator integration
    • AC coupling
    • Multi-inverter parallel operation
    • Three-phase unbalanced load support
    • Remote monitoring and energy management

    This inverter class is suitable for factories, warehouses, commercial buildings, industrial facilities, agricultural projects, EV charging stations and other C&I applications requiring both photovoltaic generation and energy storage.

    Available Power Classes


    Rated Power

    Typical Application

    30kW

    Small Commercial / Workshop / Agricultural Project

    40kW

    Commercial & Industrial

    50kW

    Commercial & Industrial

    60kW

    Medium C&I / Industrial Energy Storage

    Exact rated power, PV input configuration and battery architecture depend on the selected inverter model.

    Main Features


    Three-Phase High-Voltage C&I Architecture

    The inverter is designed for three-phase Commercial & Industrial photovoltaic and energy storage systems.

    High-voltage battery architecture allows higher system power to be transferred at relatively lower DC current compared with low-voltage battery systems.

    This is especially useful for:

    • Higher-power C&I installations
    • Longer-duration battery systems
    • High daily energy consumption
    • Peak-demand control
    • Large rooftop PV projects

    Current products in the 30–60kW class use different battery architectures, ranging from approximately 160V to 1000VDC depending on the platform. GoodWe's 40/50kW platform uses 200–800V, while current 60kW Deye platforms extend to 160–1000V.

    High-Voltage LiFePO4 Battery Compatibility


    These inverters are designed for compatible high-voltage lithium battery systems, particularly LiFePO4 energy storage batteries.

    Typical compatible battery formats include:

    • High-Voltage Rack-Mounted LiFePO4 Battery Systems
    • High-Voltage Battery Cabinets
    • Modular C&I Battery Systems
    • Outdoor C&I Battery Cabinets
    • High-Voltage Stackable Battery Systems

    Battery compatibility must be verified according to:

    • Battery voltage range
    • Nominal battery voltage
    • Maximum charge current
    • Maximum discharge current
    • Number of battery inputs
    • Battery BMS protocol
    • CAN / RS485 communication
    • Battery firmware
    • Inverter firmware

    Matching only the voltage is not sufficient to guarantee battery compatibility.

    Flexible Battery Input Architecture


    Different 30kW–60kW inverter platforms use different battery input designs.

    Single Battery Input Architecture

    Selected 40kW–50kW inverter platforms may use:

    Battery Voltage Range: Approx. 200–800VDC
    Maximum Continuous Charge Current: Approx. 100A
    Maximum Continuous Discharge Current: Approx. 100A

    This architecture is used by current GoodWe 40/50kW high-voltage hybrid products.

    Dual Battery Input Architecture

    Other C&I platforms use two independently controlled high-voltage battery inputs.

    Representative configurations include:

    70A + 70A

    or

    80A + 80A

    maximum charging/discharging current, depending on model.

    Current Solis 30–50kW systems support up to 70A+70A, while current Deye 60kW systems use dual 80A battery inputs.

    This is why the website should not state one fixed battery current for every 30–60kW model.

    Multiple MPPT Inputs


    Depending on inverter power and internal architecture, typical products may provide:

    3-6 Independent MPPTs

    Representative configurations include:

    • 30kW: Typically 3–4 MPPTs
    • 40kW: Typically 3–4 MPPTs
    • 50kW: Typically 4 MPPTs
    • 60kW: Up to 6 MPPTs on Selected Models

    Multiple MPPT trackers allow the inverter to manage PV arrays installed with:

    • Different roof orientations
    • Different tilt angles
    • Partial shading
    • Multiple roof sections
    • Different string groups

    Current GoodWe 40/50kW platforms use 3/4 MPPTs, Solis 30–50kW uses up to four MPPTs, while current Deye 60kW products use six MPPTs.

    High-Current Solar Module Compatibility

    Modern N-Type TOPCon modules can have relatively high operating and short-circuit current.

    Depending on inverter architecture, typical C&I hybrid inverters may support approximately:

    20–21A per PV string

    with approximately:

    36–42A operating current per MPPT

    on applicable dual-string MPPT platforms.

    Maximum short-circuit current per MPPT may reach approximately:

    42–55A or higher depending on model

    For example, current GoodWe C&I hybrid models provide up to 42A on selected MPPTs, while Solis specifies up to 20A string current and current Deye 60kW products use 36A operating current per MPPT.

    The exact PV module current must always be checked against the selected inverter.

    13a835d1-5250-4cce-b0a2-6f3d14

    PV Oversizing Capability


    China 30kW–60kW Three-Phase High-Voltage C&I Hybrid Solar Inverter Manufacturer, Factory | Chudu

    Selected C&I hybrid inverter models allow PV array capacity to exceed nominal inverter AC output capacity.

    Depending on model, the DC PV array may be designed above the inverter's rated AC power to improve annual solar energy utilization.

    For example, current GoodWe 40/50kW platforms support substantial DC oversizing and specify up to 150% DC oversizing in product literature.

    Actual permissible PV oversizing depends on:

    • Maximum PV input power
    • Maximum input voltage
    • MPPT operating current
    • String configuration
    • Local climate
    • Local grid requirements
    • DC/AC design ratio

    Backup Power Function


    Selected 30kW–60kW hybrid inverters can provide backup or off-grid power.

    Depending on model, backup functions may include:

    • Automatic grid-to-backup transfer
    • Three-phase backup output
    • High temporary overload capability
    • Battery-powered backup
    • PV + battery backup
    • Generator-assisted backup
    • Unbalanced three-phase loads

    Some systems require an external STS – Static Transfer Switch or approved switching equipment to enable full backup operation.

    For example, GoodWe's 40/50kW platform uses an STS box for UPS-level switching, while Solis offers backup switching below 10ms on applicable 30–50kW systems.

    Therefore, backup capability should always be confirmed according to the exact model and system design.

    Peak Shaving


    C&I hybrid inverters can work with battery storage to reduce utility-grid demand during periods of high load.

    Typical operating strategy:

    Low Site Demand → PV / Grid Charges Battery

    High Site Demand → Battery + PV Supply Loads

    This can help reduce:

    • Maximum grid demand
    • Peak electricity consumption
    • Demand charges
    • Grid capacity pressure

    Actual savings depend on local electricity tariff structure and energy management strategy.

    Time-of-Use Energy Management


    Where electricity prices vary by time period, the inverter and battery system can operate according to scheduled charging and discharging periods.

    Typical strategy:

    Low-Tariff Period → Battery Charging

    High-Tariff Period → Battery Discharging

    This function is commonly used in commercial and industrial energy storage systems for electricity cost optimization.

    Generator Integration


    Generator Integration

    Selected C&I hybrid inverter models support diesel or other generator integration.

    Functions may include:

    • Generator power input
    • Generator charging of battery
    • Automatic generator start / stop
    • PV + battery + generator operation
    • Generator-assisted backup
    • Peak shaving with generator

    Current GoodWe and Solis C&I hybrid platforms include generator integration options.

    Exact generator interface and control logic depend on the inverter model.

    AC Coupling


    Selected models support AC coupling.

    This allows an energy storage system to be added to an existing PV installation without completely replacing the existing grid-connected solar inverter.

    Typical retrofit configuration:

    Existing PV Inverter + AC Bus + Hybrid Inverter + Battery

    AC coupling capability should be confirmed before system design.

    Parallel Operation


    Selected 30kW–50kW hybrid inverter models support multiple units operating in parallel.

    Parallel operation can provide:

    • Higher total system power
    • Easier system expansion
    • Larger C&I energy storage capacity
    • Redundancy
    • Flexible project design

    For example, Solis 30–50kW platforms support multiple parallel units, and Deye high-power hybrid platforms support multi-unit parallel operation.

    Maximum parallel quantity depends on model, firmware, communication design and external switching equipment.

    Reference Technical Specifications


    Parameter

    Typical Specification

    Product Type

    Three-Phase High-Voltage C&I Hybrid Solar Inverter

    Rated AC Power

    30kW - 60kW

    Typical Power Options

    30 / 40 / 50 / 60kW

    Phase

    Three-Phase

    Battery Type

    High-Voltage Lithium / LiFePO4

    Battery Voltage Range

    Approx. 160/200V - 800/1000VDC, Model Dependent

    Number of Battery Inputs

    1 - 2, Model Dependent

    Battery Charge / Discharge Current

    Up to Approx. 100A on Selected Single-Input Models; Approx. 70A+70A or 80A+80A on Selected Dual-Input Models

    Maximum PV Input Voltage

    Typically Up to 1000VDC

    MPPT Voltage Range

    Approx. 150/165V - 850VDC, Model Dependent

    PV Start-Up Voltage

    Approx. 180 - 200VDC

    Number of MPPTs

    Typically 3 - 6

    Maximum Operating Current per MPPT

    Approx. 36 - 42A on Applicable Platforms

    Maximum PV String Current

    Approx. 20 - 21A per String on Applicable Models

    Maximum Short-Circuit Current per MPPT

    Approx. 42 - 55A or Higher, Model Dependent

    Rated AC Voltage

    380V / 400V Three-Phase

    AC Connection

    3L + N + PE on Applicable Models

    Grid Frequency

    50Hz / 60Hz

    Power Factor

    Adjustable, Model Dependent

    THDi

    Typically <3% at Rated Power on Applicable Models

    Maximum Efficiency

    Typically Approx. 98% or Higher, Model Dependent

    Backup Output

    Available on Applicable Models

    Generator Support

    Available on Selected Models

    AC Coupling

    Available on Selected Models

    Parallel Operation

    Available on Selected Models

    Unbalanced Output

    Available on Applicable Models

    Communication

    CAN / RS485 / Ethernet / Wi-Fi / 4G, Model Dependent

    Cooling

    Intelligent Fan / Forced Air Cooling

    Protection Rating

    Typically IP65 / IP66

    Operating Temperature

    Typically Approx. -35° C / -40° C to +60° C

    Installation

    Indoor / Outdoor

    Mounting

    Wall-Mounted / Floor or System Configuration Dependent

    These figures represent a range of current C&I high-voltage hybrid inverter architectures rather than one single fixed inverter platform.

    Reference Configurations by Power Class


    30kW Class

    Typical characteristics may include:

    • Three-phase AC output
    • High-voltage battery
    • 3–4 MPPTs
    • Multiple PV strings
    • Peak shaving
    • Backup output
    • Generator support
    • Parallel operation

    40kW Class

    Typical characteristics may include:

    • Approx. 200–800V battery platform on selected models
    • 3–4 MPPTs
    • Up to approximately 100A battery current on selected platforms
    • 1000V maximum PV input
    • C&I backup capability
    • Generator integration

    50kW Class

    Typical characteristics may include:

    • 3–4 MPPTs
    • Single or dual battery inputs
    • Up to approximately 100A single-port architecture or approximately 70A+70A dual-port architecture
    • High-power C&I PV compatibility
    • Parallel operation

    60kW Class

    Selected newer high-power platforms may provide:

    • Approx. 160–1000V high-voltage battery range
    • Dual battery inputs
    • Up to approximately 80A+80A charge/discharge current
    • Up to 6 MPPTs
    • 1000V maximum PV input
    • Multi-unit parallel operation

    Current Deye 60kW C&I hybrid products use this type of architecture.

    Reference PV Input Parameters


    Parameter

    Typical Range

    Maximum PV Input Voltage

    Up to Approx. 1000VDC

    Start-Up Voltage

    Approx. 180 - 200VDC

    MPPT Voltage Range

    Approx. 150/165 - 850VDC

    Rated PV Voltage

    Approx. 600 - 650VDC, Model Dependent

    Number of MPPTs

    Approx. 3 - 6

    Strings per MPPT

    1 - 2, Model Dependent

    Typical String Current

    Up to Approx. 20 - 21A per String

    Operating Current per MPPT

    Approx. 36 - 42A on Applicable Models

    Short-Circuit Current per MPPT

    Approx. 42 - 55A or Higher, Model Dependent

    Reference Battery Parameters


    Parameter

    Typical Specification

    Battery Chemistry

    Lithium / LiFePO4

    Battery Architecture

    High-Voltage

    Battery Voltage

    Approx. 160/200V - 800/1000VDC

    Battery Inputs

    1 - 2

    Single-Port Current

    Up to Approx. 100A on Applicable Models

    Dual-Port Current

    Approx. 70A+70A or 80A+80A on Applicable Models

    Communication

    CAN / RS485

    Charging Strategy

    BMS-Controlled / Self-Adaptive on Applicable Models

    Final battery compatibility must be confirmed against the inverter manufacturer's approved battery list.

    Reference AC Parameters


    Parameter

    Typical Specification

    Rated Output Power

    30kW - 60kW

    AC Phase

    Three-Phase

    Rated AC Voltage

    380V / 400V

    Grid Connection

    3L + N + PE on Applicable Models

    Frequency

    50Hz / 60Hz

    Power Factor

    Adjustable

    Output THDi

    Typically <3%

    Maximum Efficiency

    Approx. 98%+

    Backup Output

    Model Dependent

    Typical System Configuration


    A typical C&I hybrid energy storage system may include:

    **Solar PV Modules
    + 30kW–60kW Three-Phase High-Voltage Hybrid Inverter

    • High-Voltage LiFePO4 Battery System
    • EMS / Energy Management Controller
    • Smart Meter / CT
    • Utility Grid
    • AC Distribution Cabinet
    • Commercial / Industrial Loads**

    Optional equipment may include:

    • STS
    • Generator
    • EV Charger
    • Additional Hybrid Inverters
    • Existing Grid-Tied PV Inverter
    • External EMS
    • Remote Monitoring Gateway

    Typical Working Principle


    During High Solar Generation

    PV electricity supplies onsite loads first.

    Excess solar power can be used to:

    Charge Battery → Export to Grid, if permitted


    During Low Solar Generation

    The system can supply loads using:

    PV + Battery

    If additional power is required:

    Grid + PV + Battery → Loads


    During Peak Demand

    Battery energy can be discharged to reduce power purchased from the utility grid.

    PV + Battery → Loads

    This helps reduce peak grid demand.


    During Low-Tariff Periods

    Where time-of-use tariffs apply:

    Grid / PV → Battery Charging

    Stored energy can then be discharged during higher-price periods.


    During Grid Failure

    When the selected inverter and system are configured for backup:

    PV + Battery → Backup Loads

    An STS or other approved transfer device may be required depending on inverter architecture.

    C&I Battery Compatibility


    This inverter class is suitable for use with compatible products such as:

    • 20kWh–60kWh High-Voltage Rack-Mounted LiFePO4 Battery Systems
    • 100kWh–215kWh High-Voltage LFP Battery Cabinets
    • Modular High-Voltage Commercial Battery Systems
    • Outdoor C&I Battery Cabinets

    For larger battery systems, the following must be checked:

    • Battery nominal voltage
    • Operating voltage range
    • Battery power
    • Maximum charge current
    • Maximum discharge current
    • Battery capacity
    • BMS protocol
    • Number of parallel battery cabinets
    • Battery-to-inverter communication

    Solar Module Compatibility


    The inverter can be used with current high-efficiency PV modules including:

    • N-Type TOPCon Solar Modules
    • Bifacial Dual-Glass Modules
    • Monofacial Modules
    • 500W+ High-Power Modules
    • 600W+ C&I Modules
    • 700W-Class Modules on Compatible MPPT Designs

    Before connecting modules, calculate:

    • Module VOC
    • Module VMP
    • Module ISC
    • Module IMP
    • Maximum string voltage
    • Number of modules per string
    • Strings per MPPT
    • MPPT input current
    • MPPT short-circuit current
    • Minimum ambient temperature

    High module wattage alone does not determine compatibility.

    Energy Management Functions


    Depending on the selected inverter and EMS, available operating modes may include:

    • Self-Consumption Mode
    • Peak Shaving Mode
    • Time-of-Use Mode
    • Backup Power Mode
    • Battery Reserve Mode
    • Zero Export Mode
    • Export Limitation
    • Generator Mode
    • Scheduled Charging
    • Scheduled Discharging
    • Remote Energy Management

    Protection Functions


    Depending on model, integrated protection may include:

    • PV Reverse Polarity Protection
    • Battery Reverse Polarity Protection
    • DC Overvoltage Protection
    • AC Overvoltage Protection
    • AC Overcurrent Protection
    • Short-Circuit Protection
    • Anti-Islanding Protection
    • Residual Current Monitoring
    • Insulation Resistance Monitoring
    • Over-Temperature Protection
    • DC Switch
    • DC Surge Protection
    • AC Surge Protection
    • AFCI on Selected Models
    • Emergency Shutdown / Remote Shutdown on Selected Models

    Exact protection configuration must be confirmed using the selected inverter datasheet.

    Monitoring & Communication


    Available communication interfaces may include:

    • CAN
    • RS485
    • Ethernet / LAN
    • Wi-Fi
    • 4G
    • Bluetooth
    • Modbus
    • Cloud Monitoring
    • Mobile APP
    • Web Portal

    Typical monitored information includes:

    • PV generation
    • PV voltage
    • PV current
    • Battery State of Charge
    • Battery voltage
    • Battery current
    • Battery power
    • Grid import
    • Grid export
    • Load demand
    • Backup load
    • Daily energy
    • Historical energy
    • System alarms
    • Device status

    Environmental Specifications


    Environmental Specifications


    Typical C&I hybrid inverter specifications include:

    Protection Rating: IP65 / IP66

    Installation: Indoor or Outdoor

    Operating Temperature: Approx. -35°C / -40°C to +60°C

    Cooling: Intelligent Fan / Forced Air Cooling

    Maximum Operating Altitude: Model Dependent; Derating May Apply at High Altitude

    Relative Humidity: Model Dependent

    GoodWe's current 40/50kW system, for example, uses IP66 protection and smart fan cooling.

    Typical Applications


    30kW–60kW three-phase high-voltage C&I hybrid solar inverters are suitable for:

    • Manufacturing Plants
    • Factories
    • Warehouses
    • Industrial Workshops
    • Commercial Buildings
    • Shopping Centers
    • Office Buildings
    • Hotels
    • Agricultural Facilities
    • Farms
    • Logistics Centers
    • EV Charging Stations
    • Solar Carports
    • PV + Energy Storage Systems
    • Peak-Shaving Projects
    • Backup Power Systems
    • Microgrids
    • Distributed C&I Solar Projects

    Compliance & Certification


    Depending on brand, exact inverter model and destination market, applicable standards and documentation may include:

    • IEC / EN 62109-1
    • IEC / EN 62109-2
    • IEC / EN 62477-1
    • IEC 62116
    • IEC 61727
    • IEC / EN 61000 Series
    • EN 50549
    • VDE-AR-N 4105 / Applicable German Grid Standards
    • G99 / Applicable UK Grid Standards
    • NRS 097
    • CE Documentation
    • Country-Specific Grid Certifications

    Current Solis C&I hybrid products, for example, list IEC/EN 62109, IEC/EN 62477 and IEC/EN 61000 family compliance documentation.

    Certification should always be verified according to the exact model + destination country + local grid requirements.

    Information Required for Quotation


    Please provide:

    • Required Power: 30kW / 40kW / 50kW / 60kW
    • Destination Country
    • Destination Port
    • Grid Voltage
    • Grid Frequency
    • PV System Capacity
    • Solar Module Wattage
    • Solar Module VOC / VMP / ISC / IMP
    • Required Battery Capacity
    • Battery Brand and Model, if already selected
    • Battery Voltage Range
    • Required Charge / Discharge Power
    • Peak Load
    • Daily Electricity Consumption
    • Required Backup Load
    • Required Backup Time
    • Whether Generator Integration Is Required
    • Whether AC Coupling Is Required
    • Whether Parallel Operation Is Required
    • Required Communication Interface
    • Required Grid Certification
    • Required Quantity
    • EXW / FOB / CIF Requirement

    If the battery and inverter have not yet been selected, project load data, PV capacity and destination-country information can be provided so that a suitable configuration can be recommended.

    Packing & Shipping


    The inverter is normally packed individually with protective carton packaging and internal protective material.

    Typical package contents may include:

    • C&I Hybrid Inverter
    • Mounting Accessories
    • PV Connectors
    • Battery Connectors
    • Communication Accessories
    • Meter / CT Accessories, Model Dependent
    • Installation Hardware
    • User Manual

    Exact dimensions, net weight, gross weight and pallet quantity depend on the selected inverter model.

    Trade Terms


    EXW / FOB / CIF

    Please contact us for:

    • Current Stock
    • Latest Price
    • Available Brands
    • Exact Model Numbers
    • Official Datasheets
    • Battery Compatibility Information
    • Grid Certification Documents
    • Packing Information
    • Container Loading Information
    • Shipping Quotation

    Chudu Metal

    Solar PV Modules, Solar Inverters, Energy Storage Batteries & Solar Mounting Components Supplier from China
    🌐 Website:  www.chudufastener.com
    📧 Email:  han@hbchudu.com
    📱 WhatsApp / Phone: +86 19333039217

    description2

    Contact Us

    Our experts will solve them in no time.