20kWh–60kWh High-Voltage Rack-Mounted LiFePO4 Battery System



Product Overview
Chudu Metal 20kWh–60kWh High-Voltage Rack-Mounted LiFePO4 Battery Systems are designed for residential, commercial, off-grid and backup energy storage applications requiring higher battery voltage and modular capacity expansion.
The system uses Lithium Iron Phosphate (LiFePO4 / LFP) battery modules installed in a rack or battery cabinet. Multiple 51.2V battery modules are connected in series to form a high-voltage battery cluster.
Typical system capacities range from approximately 20.48kWh to 61.44kWh, with nominal system voltage from approximately 204.8VDC to 614.4VDC, depending on the number of battery modules installed.
Current mainstream rack systems use 5.12kWh / 51.2V / 100Ah modules, generally with 4–12 modules connected in series for systems between approximately 20kWh and 60kWh.
The system normally consists of battery modules, a high-voltage battery control unit, BMS, DC protection, communication cables and a rack or cabinet.
It can be connected to a compatible high-voltage hybrid inverter, PCS or energy storage inverter.
Main Features
High-Voltage Battery Architecture
Multiple battery modules are connected in series to increase the DC voltage while maintaining the same amp-hour capacity.
Typical configurations provide:
204.8VDC-614.4VDC nominal system voltage
with system operating voltage approximately:
166.4VDC-700VDC
depending on the selected configuration.
Deye's current BOS-G system uses 4–12 modules for 20.48–61.44kWh systems, with nominal voltages from 204.8V to 614.4V.
5.12kWh Modular Battery Design
A typical battery module provides:
51.2V / 100Ah / 5.12kWh
This modular design allows different system capacities to be created by adjusting the number of battery modules.
Current Deye BOS-G Pro and Dyness HV51100 modules use this same 51.2V / 100Ah / 5.12kWh format.
Lithium Iron Phosphate Technology
The system uses LiFePO4 / LFP battery chemistry, providing:
- High thermal stability
- Long cycle life
- Stable charge and discharge performance
- Good safety characteristics
- Low maintenance
- No memory effect
- Suitability for frequent energy cycling
Integrated Battery Management System
The system is equipped with an intelligent Battery Management System.
Depending on configuration, BMS functions may include:
- Cell voltage monitoring
- Module voltage monitoring
- System voltage monitoring
- Charge current monitoring
- Discharge current monitoring
- Cell temperature monitoring
- State of Charge (SoC)
- State of Health (SoH), where supported
- Cell balancing
- Overvoltage protection
- Undervoltage protection
- Overcurrent protection
- Short-circuit protection
- Over-temperature protection
- Low-temperature protection
- Communication fault monitoring
- Alarm and shutdown functions
High-Voltage Control Unit
A high-voltage battery cluster normally includes a dedicated:
Battery Distribution Unit / Battery Control Unit / High-Voltage Box
depending on system design.
The control unit manages high-voltage output, system communication and electrical protection between the battery rack and compatible PCS or inverter.
Deye's current BOS-G Pro uses a dedicated high-voltage battery cluster control box rated for 200–1000VDC.
Modular Capacity Expansion
Typical configurations include:
20.48kWh / 25.60kWh / 30.72kWh / 35.84kWh / 40.96kWh / 46.08kWh / 51.20kWh / 56.32kWh / 61.44kWh
System capacity is adjusted by changing the number of series-connected battery modules.
Long Cycle Life
Selected high-voltage rack-mounted LFP battery systems provide:
6,000+ cycles
under specified testing conditions.
Deye BOS-G specifies 36,000 cycles at 25±2°C, 0.5C charge/discharge and 70% end-of-life capacity; Dyness HV51100 also specifies more than 6,000 cycles under its stated conditions.
High Depth of Discharge
Recommended Depth of Discharge is typically:
90%–95%, depending on battery model and warranty conditions
Deye BOS-G specifies 90% recommended DoD, while Dyness HV51100 cycle-life testing is stated at 95% DoD.
CAN and RS485 Communication
Depending on the selected configuration, communication interfaces can include:
CAN / CAN2.0 / RS485
These interfaces allow communication between the BMS and compatible high-voltage inverter or PCS.
Rack-Mounted Installation
Battery modules are designed for installation inside a battery rack or cabinet.
Selected systems use a 19-inch rack-mounted structure, making module arrangement, cable management and maintenance more convenient. Deye describes BOS-G as a standard rack-mounted modular high-voltage battery architecture.
Technical Specifications
Parameter |
Specification |
Product Type |
High-Voltage Rack-Mounted LiFePO4 Battery System |
Battery Chemistry |
Lithium Iron Phosphate (LiFePO4 / LFP) |
Typical System Energy |
Approx. 20.48kWh–61.44kWh |
Battery Module Energy |
Typically 5.12kWh |
Battery Module Voltage |
Typically 51.2V |
Battery Module Capacity |
Typically 100Ah |
Battery Modules in Series |
Typically 4–12 Units |
Nominal System Voltage |
Approx. 204.8VDC–614.4VDC |
System Operating Voltage |
Approx. 166.4VDC–700VDC, Model Dependent |
Usable Energy |
Typically Approx. 90%–95% of Nominal Energy, Model Dependent |
Recommended Charge Current |
Typically Approx. 50A |
Recommended Discharge Current |
Typically Approx. 50A |
Maximum Continuous Current |
Up to Approx. 100A on Selected Models |
Peak Discharge Current |
Up to Approx. 125A for Short Duration on Selected Models |
Rated DC Power |
Model Dependent; Up to Approx. 20.48kW–61.44kW on Applicable Architectures |
Recommended Depth of Discharge |
Approx. 90%–95%, Model Dependent |
Cycle Life |
≥6,000 Cycles on Selected Models under Specified Conditions |
Battery Management System |
Integrated BMS |
High-Voltage Control Unit |
BDU / Battery Control Unit / High-Voltage Box |
Communication |
CAN / CAN2.0 / RS485 |
Cell Balancing |
Supported |
Status Monitoring |
SoC / Voltage / Current / Temperature / Alarm Status |
Installation |
Rack-Mounted / Cabinet-Mounted |
Rack Type |
19-Inch Standard Rack on Applicable Models |
Protection Rating |
Typically IP20 |
Charging Temperature |
Typically 0°C to 55°C |
Discharging Temperature |
Typically -20°C to 55°C |
Storage Temperature |
Typically 0°C to 35°C |
Relative Humidity |
Typically 5%–95%, Model Dependent |
Installation Altitude |
Typically Up to Approx. 2,000m without Derating on Applicable Models |
Cooling Method |
Natural / Passive Cooling, Model Dependent |
Compatible Equipment |
High-Voltage Hybrid Inverter / PCS / Energy Storage Inverter |
Application |
Residential / Small Commercial / Off-Grid / Backup / Solar Energy Storage |
Warranty |
According to Selected Model and Warranty Conditions |
The current BOS-G specification lists 50A recommended current, 100A nominal current and 125A peak discharge current, while operating temperature is 0–55°C for charging and -20–55°C for discharge.
Typical Capacity Configurations
Battery Modules |
Nominal Energy |
Nominal Voltage |
Typical Operating Voltage |
4 Modules |
20.48kWh |
204.8V |
166.4–233.6V |
5 Modules |
25.60kWh |
256.0V |
208–292V |
6 Modules |
30.72kWh |
307.2V |
249.6–350.4V |
7 Modules |
35.84kWh |
358.4V |
291.2–408.8V |
8 Modules |
40.96kWh |
409.6V |
332.8–467.2V |
9 Modules |
46.08kWh |
460.8V |
374.4–525.6V |
10 Modules |
51.20kWh |
512.0V |
416–584V |
11 Modules |
56.32kWh |
563.2V |
457.6–642.4V |
12 Modules |
61.44kWh |
614.4V |
499.2–700V |
These representative values correspond to the current Deye BOS-G architecture using 51.2V / 5.12kWh modules.
Typical Usable Energy
For a system configured around approximately 90% DoD, representative usable energy is:
Nominal Energy |
Approx. Usable Energy |
20.48kWh |
18.43kWh |
25.60kWh |
23.04kWh |
30.72kWh |
27.64kWh |
35.84kWh |
32.25kWh |
40.96kWh |
36.86kWh |
46.08kWh |
41.47kWh |
51.20kWh |
46.08kWh |
56.32kWh |
50.68kWh |
61.44kWh |
55.29kWh |
Actual usable energy depends on BMS settings, inverter settings, DoD, temperature and system configuration. Deye publishes the same usable-energy values for its BOS-G series based on its specified test conditions.
Typical Battery Module Parameters
A representative 5.12kWh high-voltage rack battery module can have:
Parameter |
Typical Specification |
Battery Chemistry |
LiFePO4 |
Nominal Energy |
5.12kWh |
Nominal Voltage |
51.2V |
Rated Capacity |
100Ah |
Typical Dimensions |
Approx. 440–481mm W × 535–585mm D × 133–140mm H |
Typical Weight |
Approx. 43.5–46kg |
Communication |
CAN / System Communication via Control Unit |
Protection Rating |
Typically IP20 |
Current Deye BOS-G Pro modules are approximately 440×585×133mm and 46kg, while Dyness HV51100 modules are approximately 481×535×140mm and 43.5kg.
Working Principle
Solar PV modules generate DC electricity, which is converted and managed by a compatible high-voltage hybrid inverter or PCS.
When photovoltaic generation exceeds the instantaneous load demand, excess electricity can be used to charge the high-voltage battery system.
When photovoltaic generation is insufficient, at night, or during a grid outage in a compatible backup system, stored battery energy is discharged through the inverter or PCS to supply electrical loads.
Battery modules are connected in series to increase system voltage.
The BMS and high-voltage control unit continuously monitor battery voltage, current, temperature and operating status.

Typical System Configuration
A typical system can consist of:
**Solar PV Modules
- High-Voltage Hybrid Inverter / PCS
- High-Voltage Battery Control Unit
- Rack-Mounted LiFePO4 Battery Modules
- Battery Rack / Cabinet
- DC Protection
- CAN / RS485 Communication
- AC Distribution
- Utility Grid
- Electrical Loads**
Applications
This high-voltage rack-mounted battery system is suitable for:
- Large residential solar storage
- Villas
- Small commercial buildings
- Offices
- Shops
- Farms
- Workshops
- Small factories
- Off-grid solar systems
- Backup power systems
- Microgrids
- Solar + Storage projects
- Areas with unstable utility grids
Deye specifically positions its BOS-G system for applications such as supermarkets, banks, schools, farms and small factories.
High-Voltage Rack Battery vs. 51.2V Low-Voltage Rack Battery
The two products should not be confused.
51.2V Low-Voltage Rack Battery
Battery modules are normally connected in parallel.
Parallel connection increases:
Ah capacity and kWh energy
while nominal voltage remains approximately:
51.2V
High-Voltage Rack Battery System
Battery modules are primarily connected in series.
Series connection increases:
system voltage and total energy
For example:
4 × 51.2V modules = 204.8V
8 × 51.2V modules = 409.6V
12 × 51.2V modules = 614.4V
This high-voltage architecture is intended for compatible high-voltage inverters or PCS.
Monitoring & Communication
Depending on the battery, inverter and monitoring configuration, users may monitor:
- State of Charge
- Battery voltage
- Battery current
- Charge power
- Discharge power
- Battery temperature
- Charging status
- Discharging status
- BMS alarms
- Protection status
- Historical operating data
Compatible Inverter Requirements
Before quotation or system configuration, the following inverter parameters should be confirmed:
- Inverter brand and model
- High-voltage battery input range
- Maximum battery charge current
- Maximum battery discharge current
- Battery communication protocol
- CAN / RS485 compatibility
- Minimum and maximum number of battery modules
- Inverter firmware version
- Maximum supported battery energy
- Approved battery compatibility list
Battery voltage alone is not sufficient to confirm compatibility.
Environmental Requirements
Rack-mounted battery modules are commonly intended for protected indoor installation.
Typical IP20 battery modules should be protected from:
- Rain
- Direct water exposure
- Excessive moisture
- Conductive dust
- Extreme ambient temperatures
Installation requirements must follow the selected battery model's technical manual.
Safety & Protection
Depending on configuration, the battery system may provide:
- Cell overvoltage protection
- Cell undervoltage protection
- Module overvoltage protection
- Module undervoltage protection
- Charge overcurrent protection
- Discharge overcurrent protection
- Short-circuit protection
- Over-temperature protection
- Low-temperature charging protection
- Cell balancing
- Insulation monitoring on selected systems
- Communication fault protection
- System alarm
- Emergency shutdown
- DC high-voltage isolation
Some systems also incorporate additional rack-level fire-protection functions. Deye describes aerosol fire extinguishing in its BOS-G rack system architecture.
Monitoring & Communication
Depending on the selected BMS and inverter, the system can monitor:
- State of Charge
- State of Health
- Battery voltage
- Battery current
- Charge power
- Discharge power
- Cell voltage
- Battery temperature
- Alarm status
- Protection status
- Communication status
- Historical operating data
Communication interfaces typically include:
CAN / CAN2.0 / RS485
Installation Requirements
Before installation, confirm:
- Correct rack dimensions
- Rack load-bearing capacity
- Battery module quantity
- High-voltage control-unit position
- DC cable routing
- Communication cable routing
- Grounding
- Ventilation
- Required installation clearances
- Inverter voltage compatibility
- Battery polarity
- Emergency isolation requirements
Because each 5.12kWh module typically weighs approximately 44–46kg, the complete rack can weigh several hundred kilograms depending on system capacity.
Environmental Requirements
These rack-mounted systems are generally designed for indoor installation.
Typical enclosure protection is:
IP20
Representative operating conditions include:
Charging: 0°C to 55°C
Discharging: -20°C to 55°C
Storage: approximately 0°C to 35°C
If outdoor installation is required, the battery rack should be installed inside a suitable outdoor-rated enclosure or battery room designed for the environmental conditions.
Compliance, Safety & Transport Documentation
Depending on the selected model and destination market, applicable certificates or documentation can include:
- IEC 62619
- CE
- EMC
- UL 1973
- UL 9540A
- UN38.3
- SDS
- VDE Requirements
- Other Regional Requirements
Deye's BOS-G documentation lists combinations including CE, IEC 62619, UL1973, UL9540A and UN38.3 depending on version and target market, while Dyness HV51100 documentation lists CE/EMC and UN38.3.
Actual certification must be confirmed according to the specific supplied model.
UN38.3 is lithium-battery transport testing/documentation. SDS is safety documentation and should not be described simply as a product certification.
Information Required for Quotation
For accurate configuration and quotation, please provide:
- Required battery capacity
- Required backup duration
- Inverter or PCS brand and model
- Inverter battery voltage range
- Maximum charge/discharge current
- Solar PV system capacity
- Daily electricity consumption
- Maximum load power
- Required battery module quantity
- Required rack or cabinet configuration
- Installation location
- Ambient temperature
- Destination country
- Required certifications
- Required communication protocol
Packing & Shipping
Battery modules and high-voltage control equipment are packed separately or inside the battery rack depending on shipment requirements and system design.
Lithium battery transportation may require:
UN38.3 Test Documentation
SDS
Dangerous Goods Declaration
Battery Transport Documentation
Specialized Export Packaging
Battery racks and modules should be protected against impact, moisture, incorrect stacking and terminal short circuit during transportation.
Chudu Metal
Solar PV Modules, Solar Mounting Components & Solar Product Supplier from China
🌐 Website: www.chudufastener.com
📧 Email: han@hbchudu.com
📱 WhatsApp / Phone: +86 19333039217
description2
Contact Us
- barry@hbchudu.com
- +86 18533933520
-
Hebei Chudu Metal Products Co., Ltd.
Our experts will solve them in no time.


Phone
Facebook
Youtube