15kW–30kW Three-Phase High-Voltage Hybrid Solar Inverter



Product Overview
Chudu Metal supplies 15kW–30kW three-phase high-voltage hybrid solar inverters for large residential, villa, commercial, agricultural and small industrial photovoltaic energy storage systems.
Available rated power classes typically include:
15kW / 20kW / 25kW / 29.9kW / 30kW
The inverter integrates photovoltaic power conversion, high-voltage battery charge and discharge management, grid interaction, load management and backup power functions into one energy management platform.
Depending on the selected brand and model, available functions may include:
- Grid-connected solar generation
- High-voltage battery energy storage
- Backup / EPS output
- Peak shaving
- Time-of-use energy management
- PV self-consumption
- Export power limitation
- Unbalanced three-phase load support
- Generator integration
- AC coupling
- Multi-inverter parallel operation
- Remote monitoring
Current mainstream products in this class use approximately 160–800VDC high-voltage battery platforms, up to three MPPTs, and 1000V maximum PV input voltage, with exact specifications varying by model.
Available Power Classes
Rated Power |
Typical Application |
15kW |
Large Residential / Villa / Small Commercial |
20kW |
Residential / Commercial / Agricultural |
25kW |
Commercial / Small Industrial |
29.9kW |
Commercial & Industrial |
30kW |
Commercial & Industrial |
Exact power options depend on the selected inverter manufacturer and destination market.
Main Features
Three-Phase High-Voltage Hybrid Architecture
The inverter is designed for three-phase AC systems and compatible high-voltage lithium battery systems.
Compared with low-voltage battery architectures, high-voltage battery systems can operate at lower DC current for the same power level, helping reduce cable current and conversion losses in higher-power energy storage applications.
Typical battery voltage ranges across current platforms are approximately:
160VDC–800VDC
Actual minimum and maximum battery voltage must be matched to the selected inverter and battery system.
High-Voltage LiFePO4 Battery Compatibility
The inverter is designed primarily for compatible high-voltage lithium battery systems, including LiFePO4 energy storage batteries.
Typical battery communication protocols include:
CAN / RS485
Battery compatibility must be confirmed according to to:
- Battery brand
- Battery model
- Battery voltage range
- Maximum charge current
- Maximum discharge current
- BMS communication protocol
- Battery firmware
- Inverter firmware
Battery voltage alone is not sufficient to confirm inverter compatibility.
Multiple MPPT Inputs
Depending on rated power and inverter architecture, the inverter can provide approximately:
2–3 independent MPPTs
Multiple MPPT trackers help optimize photovoltaic energy generation where solar arrays have:
- Different roof orientations
- Different tilt angles
- Partial shading
- Multiple string groups
- Different rooftop areas
Current 15–20kW platforms commonly use two MPPTs, while 25–30kW platforms frequently use three MPPTs.
High-Power Solar Module Compatibility
Modern high-power solar modules have increased operating current.
Representative current 15–30kW hybrid inverter platforms provide approximately:
30A–36A maximum operating PV input current per MPPT
and approximately:
38A–54A maximum short-circuit current per MPPT
depending on the selected inverter.
This makes applicable models compatible with many current high-current N-Type TOPCon solar modules when string design is correctly calculated.
PV Oversizing
Selected hybrid inverter models allow photovoltaic array capacity to exceed nominal inverter AC output power.
This can improve annual solar energy utilization during periods of lower irradiation.
The permitted DC/AC ratio depends on:
- Inverter model
- MPPT current
- Maximum PV input power
- Local grid regulations
- Solar array orientation
- Ambient temperature
Final PV oversizing should always be calculated according to the exact inverter datasheet.
Backup Power Function
Selected models provide dedicated backup / EPS output for critical loads.
Applicable functions may include:
- Automatic backup supply
- UPS-level transfer
- Three-phase backup output
- Unbalanced load support
- Temporary overload capability
Selected current products support backup switching below approximately 10 ms, while overload capability varies according to model.
Backup operation should not be assumed for every inverter configuration and must be confirmed before quotation.
Unbalanced Three-Phase Output
Selected models support 100% unbalanced output, allowing different loads to be supplied on different phases.
This can be useful in:
- Residential buildings
- Shops
- Offices
- Farms
- Workshops
- Commercial buildings
where individual phase loading may not be perfectly balanced.
Current three-phase high-voltage hybrid inverter platforms include models with 100% unbalanced operation.
Peak Shaving
The inverter can coordinate battery charging and discharging to reduce power drawn from the utility grid during periods of high demand.
Peak-shaving applications can be useful for:
- Commercial buildings
- Workshops
- Farms
- Small factories
- High-demand residential properties
where peak grid demand or time-of-use electricity pricing affects operating costs.
Time-of-Use Energy Management
With a compatible battery and monitoring system, charging and discharging schedules can be configured according to electricity tariffs.
Typical operating strategy:
Charge during lower-price periods → Store energy → Discharge during higher-price periods
Actual economic benefit depends on local electricity tariffs and system operating strategy.
Generator Integration
Selected inverter models support generator integration.
Depending on inverter design, generator functions may include:
- Generator input
- Battery charging from generator
- Generator start/stop control
- Generator + PV + battery operation
- Backup power support
Generator compatibility must be confirmed according to the exact inverter model.
AC Coupling
Selected models can support AC coupling to integrate existing grid-connected PV inverter systems with a new battery storage system.
This can be useful for retrofit projects where an existing solar PV system is already installed.
AC-coupling capability is model dependent.
Parallel Operation
Selected inverter models support multiple units operating in parallel.
Parallel operation can be used to:
- Increase system power
- Expand energy storage projects
- Support larger commercial loads
- Improve system flexibility
The maximum number of parallel inverters depends on model and firmware.
Some current 25–30kW high-voltage hybrid products support up to 10 parallel inverter units.
Reference Technical Specifications
Parameter |
Typical Specification |
Product Type |
Three-Phase High-Voltage Hybrid Solar Inverter |
Rated AC Power |
15kW – 30kW |
Typical Power Options |
15 / 20 / 25 / 29.9 / 30kW |
Phase |
Three-Phase |
Battery Type |
High-Voltage Lithium / LiFePO4 |
Battery Voltage Range |
Approx. 160 – 800VDC Across Applicable Platforms |
Typical Battery Inputs |
1 – 2, Model Dependent |
Max. Charge Current |
Approx. 50 – 75A per Battery Input; Dual-Input Architecture Available |
Max. Discharge Current |
Approx. 50 – 75A per Battery Input; Dual-Input Architecture Available |
Maximum PV Input Voltage |
Typically Up to 1000VDC |
MPPT Voltage Range |
Approx. 150/200 – 850VDC, Model Dependent |
Start-Up Voltage |
Approx. 180 – 200VDC |
Number of MPPTs |
Typically 2 – 3 |
Strings per MPPT |
Typically 2 Strings per MPPT on Applicable Models |
Max. Operating Current per MPPT |
Approx. 30 – 36A, Model Dependent |
Max. Short-Circuit Current per MPPT |
Approx. 38 – 54A, Model Dependent |
Rated AC Voltage |
380VAC / 400VAC, Market Dependent |
AC Connection |
Three-Phase 3L+N+PE on Applicable Models |
Grid Frequency |
50Hz / 60Hz |
Power Factor |
Adjustable, Model Dependent |
AC Current THD |
Typically <3% on Applicable Models |
Maximum Efficiency |
Approx. 98.0% – 98.5% |
MPPT Efficiency |
Typically >99% |
Backup Output |
Available on Applicable Models |
Backup Switching |
UPS-Level / Fast Transfer on Selected Models |
Unbalanced Output |
Up to 100% on Selected Models |
Parallel Operation |
Available on Selected Models |
Generator Support |
Available on Selected Models |
Communication |
CAN / RS485 / Ethernet / Wi-Fi / 4G / Bluetooth, Model Dependent |
Protection Rating |
Typically IP65 / IP66 |
Cooling |
Intelligent Air Cooling / Fan Cooling |
Operating Temperature |
Typically Approx. -35° C / -40° C to +60° C |
Installation Altitude |
Typically Up to Approx. 3000m before or subject to Derating |
Installation |
Wall-Mounted / Outdoor or Indoor |
Warranty |
According to Selected Brand, Model and Market |
These ranges reflect current commercial 15–30kW platforms rather than one single inverter design. GoodWe's current range uses 200–800V batteries, 50A or 50A×2 battery current and 30A/MPPT; Deye's current 25–30kW platform uses 160–700V, 75A battery current and 36A/MPPT.
Reference Battery Input Configurations
Different inverter architectures can use different battery input arrangements.
Representative Architecture A
Typical for some 15kW–20kW models:
Battery Voltage: 200–800VDC
Battery Inputs: 1
Max. Charge Current: Approx. 50A
Max. Discharge Current: Approx. 50A
Representative Architecture B
Typical for some 25kW–30kW models:
Battery Voltage: 200–800VDC
Battery Inputs: 2
Max. Charge Current: Up to Approx. 50A × 2
Max. Discharge Current: Up to Approx. 50A × 2
Representative Architecture C
Available on other current 25kW–30kW platforms:
Battery Voltage: Approx. 160–700VDC
Battery Inputs: 1
Max. Charge Current: Up to Approx. 75A
Max. Discharge Current: Up to Approx. 75A
These architectures should not be mixed into one fixed parameter set.
Reference PV Input Parameters
Typical current platforms can provide:
Parameter |
Reference Range |
Maximum PV Input Voltage |
Up to 1000VDC |
Start-Up Voltage |
Approx. 180 – 200VDC |
MPPT Operating Range |
Approx. 150/200 – 850VDC |
Rated PV Input Voltage |
Approx. 600 – 620VDC |
Number of MPPTs |
2 – 3 |
Max. Operating Current per MPPT |
Approx. 30 – 36A |
Max. Short-Circuit Current per MPPT |
Approx. 38 – 54A |
The exact PV string configuration must be calculated according to the selected inverter and solar module.
Reference AC Parameters
Parameter |
Typical Specification |
Rated AC Output Power |
15kW – 30kW |
Rated Voltage |
380V / 400V Three-Phase |
Grid Connection |
3L+N+PE on Applicable Models |
Frequency |
50Hz / 60Hz |
Power Factor |
Adjustable |
THDi |
Typically <3% at Rated Operation |
Maximum Efficiency |
Approx. 98.0% – 98.5% |
Current representative 25–30kW units reach maximum efficiencies around 98.5%.

Typical System Configuration
A typical three-phase high-voltage hybrid solar system can include:
**Solar PV Modules
- Three-Phase High-Voltage Hybrid Inverter
- High-Voltage LiFePO4 Battery System
- Smart Meter / CT
- Utility Grid
- AC Distribution
- Critical Loads
- Normal Loads**
Optional equipment can include:
- Generator
- EV Charger
- External EMS
- Smart Loads
- Backup Transfer Equipment
- Additional Parallel Inverters
Working Principle
During daytime, solar PV modules generate DC electricity.
The hybrid inverter converts PV power into AC electricity for onsite loads.
If solar generation exceeds current load demand, excess energy can be used to:
- Charge the battery
- Export power to the grid where permitted
- Limit export according to configured grid requirements
When solar generation is insufficient, battery energy can be discharged through the inverter to supply loads.
If the battery reaches its configured minimum State of Charge, additional power can be supplied by the utility grid.
During a grid outage, applicable inverter models can supply selected backup loads using photovoltaic and battery energy.
Typical Energy Flow
Daytime with High Solar Generation
PV → Loads → Battery Charging → Grid Export, if permitted
Daytime with Low Solar Generation
PV + Battery → Loads
Night
Battery → Loads
Low Battery State of Charge
Grid → Loads
and, if configured:
Grid → Battery Charging
Grid Failure
For applicable backup systems:
PV + Battery → Backup Loads
Compatible High-Voltage Battery Systems
Depending on inverter model, compatible battery systems can include:
- High-Voltage Stackable LiFePO4 Batteries
- High-Voltage Pack-Mounted Battery Systems
- High-Voltage Battery Cabinets
- Modular Residential Energy Storage Batteries
- Small Commercial Battery Systems
Before selecting a battery, confirm:
- Minimum Battery Voltage
- Maximum Battery Voltage
- Nominal Battery Voltage
- Maximum Charge Current
- Maximum Discharge Current
- BMS Protocol
- CAN / RS485 Compatibility
- Minimum Number of Battery Modules
- Maximum Number of Battery Modules
- Battery Firmware
- Inverter Firmware
PV Module Compatibility
The inverter can be used with modern high-efficiency solar modules including:
- N-Type TOPCon Modules
- Monofacial Solar Modules
- Bifacial Solar Modules
- Dual-Glass Solar Modules
- High-Power C&I Modules
String design must verify:
- Module Voc
- Module Vmp
- Module Isc
- Module Imp
- Inverter maximum PV voltage
- MPPT voltage range
- MPPT operating current
- MPPT short-circuit current
- Minimum site temperature
- Number of modules per string
- Number of strings per MPPT
High-current modules should only be connected when the inverter MPPT current and short-circuit-current limits are sufficient.
Peak Shaving & Load Management
For commercial applications, the inverter can work with a battery energy storage system to limit power imported from the utility grid.
When site demand rises above a configured level:
Battery Energy → Hybrid Inverter → Site Loads
When demand decreases:
PV / Grid → Battery Charging
Actual savings depend on local electricity tariffs, peak-demand charges and operating strategy.
Backup Power Design
For projects requiring backup power, please confirm:
- Required backup load
- Maximum starting current
- Three-phase load distribution
- Required backup duration
- Battery capacity
- Inverter backup power
- Inverter overload capability
- Transfer time
- Generator integration requirement
- Whether full-site or critical-load backup is required
The backup output rating should not automatically be assumed to equal all grid-connected overload specifications.
Protection Functions
Depending on the selected inverter, available protection functions may include:
- DC Reverse Polarity Protection
- PV Overvoltage Protection
- Battery Reverse Polarity Protection
- AC Output Overcurrent Protection
- AC Output Overvoltage Protection
- AC Short-Circuit Protection
- Over-Temperature Protection
- Anti-Islanding Protection
- Insulation Resistance Detection
- Residual Current Monitoring
- DC Component Monitoring
- DC Switch
- Type II DC Surge Protection
- Type II AC Surge Protection
- Arc Fault Circuit Interrupter (AFCI) on Selected Models
Current 15–30kW products offer different combinations of these functions, so final protection configuration should be verified by exact model.
Monitoring & Communication
Depending on model, communication and monitoring options can include:
- RS485
- CAN
- Ethernet / LAN
- Wi-Fi
- 4G
- Bluetooth
- Cloud Monitoring Platform
- Mobile App
- Web Portal
Typical monitored parameters include:
- PV power
- PV voltage
- PV current
- Battery State of Charge
- Battery voltage
- Battery current
- Charge/discharge power
- Grid power
- Load power
- Backup power
- Daily energy production
- Historical energy data
- Alarm information
- Operating status
Environmental Specifications
Typical current inverter specifications include:
Operating Temperature: approximately -35°C / -40°C to +60°C
Protection Rating: IP65 / IP66
Installation: Indoor / Outdoor
Cooling: Intelligent air cooling
Operating Humidity: Model Dependent
Installation Altitude: typically up to approximately 3000m, with derating requirements on applicable models
Current representative products use IP65 or IP66 enclosures and intelligent air cooling.
Applications
15kW–30kW three-phase high-voltage hybrid solar inverters are suitable for:
- Large Residential Solar Systems
- Villas
- Commercial Buildings
- Shops
- Offices
- Farms
- Agricultural Facilities
- Workshops
- Small Factories
- Warehouses
- Solar + Battery Storage Systems
- Backup Power Systems
- Peak-Shaving Systems
- Distributed C&I Solar Projects
- Microgrid Applications
Compliance & Certification
Depending on brand, model and destination market, applicable standards and certifications may include:
- IEC / EN 62109-1
- IEC / EN 62109-2
- IEC 61727
- IEC 62116
- IEC / EN 61000 Series
- EN 50549
- VDE-AR-N 4105
- G99
- NRS 097
- CE Requirements
- Country-Specific Grid Connection Standards
Actual certification coverage must be confirmed according to the exact inverter model and destination country. Current products in this class are offered with different regional grid-compliance packages.
Information Required for Quotation
Please provide:
- Required Inverter Power: 15kW / 20kW / 25kW / 29.9kW / 30kW
- Destination Country
- Grid Voltage
- Grid Frequency
- Three-Phase Grid Type
- Solar PV Capacity
- Solar Module Wattage
- Solar Module Voc / Vmp / Isc / Imp
- Required Battery Capacity
- Battery Brand and Model, if already selected
- Battery Voltage Range
- Required Backup Load
- Whether Backup Output Is Required
- Whether Generator Integration Is Required
- Whether Parallel Operation Is Required
- Required Communication Method
- Required Grid Certification
- Required Quantity
- Destination Port
- EXW / FOB / CIF Requirement
If the battery or PV module has not yet been selected, customers can provide project capacity, load information and destination country, and suitable system configurations can be recommended.
Packing & Shipping
Inverters are normally packed individually with protective cartons and internal foam.
Typical package contents may include:
- Hybrid Inverter
- Mounting Bracket
- Communication Accessories
- Current Transformer / Meter Accessories, Model Dependent
- Connectors
- Installation Hardware
- User Manual
Exact packaging dimensions, gross weight and pallet quantity depend on the selected brand and model.
Trade Terms
EXW / FOB / CIF
Please contact us for:
- Current Stock
- Latest Price
- Available Brands
- Exact Model Numbers
- Official Datasheets
- Certification Documents
- Packing Information
- Container Loading Details
- Shipping Quotation
Chudu Metal
Solar PV Modules, Solar Inverters, Energy Storage Batteries & Solar Mounting Components Supplier from China
🌐 Website: www.chudufastener.com
📧 Email: han@hbchudu.com
📱 WhatsApp / Phone: +86 19333039217
description2
Contact Us
- barry@hbchudu.com
- +86 18533933520
-
Hebei Chudu Metal Products Co., Ltd.
Our experts will solve them in no time.


Phone
Facebook
Youtube