10kW–20kW Three-Phase Grid-Tied String Solar Inverter



Product Overview
Chudu Metal supplies 10kW–20kW three-phase grid-tied string solar inverters for large residential, commercial, industrial, agricultural and distributed photovoltaic systems.
Typical available rated powers include:
10kW / 12kW / 15kW / 17kW / 20kW
The inverter converts DC power generated by photovoltaic modules into three-phase AC electricity synchronized with the utility grid.
It is suitable for projects requiring higher three-phase output power than typical residential single-phase systems.
Current mainstream three-phase platforms in this power class commonly use two independent MPPTs and are designed for modern high-power solar modules.
GoodWe currently positions its 4–20kW SDT G3 as a two-MPPT three-phase platform, while Sungrow offers dedicated 15–20kW three-phase string inverters.
Important: 10kW products are available in both single-phase and three-phase versions in the international market. The required grid phase must therefore be confirmed before quotation.
Available Power Classes
Rated Power |
Typical Application |
10kW |
Large Residential / Small Commercial |
12kW |
Residential / Commercial |
15kW |
Commercial / Agricultural |
17kW |
Commercial |
20kW |
Commercial / Small Industrial |
Exact rated-power availability depends on brand, model and destination market.
Three-Phase Grid-Connected Architecture
Typical AC system options include:
220/380V
230/400V
240/415V
depending on destination-country grid requirements.
Typical AC connection:
3L + N + PE
on applicable models.
Three-phase inverters are particularly suitable for commercial or industrial facilities where electrical loads are distributed across three phases.
High-Voltage DC Input Platform
Unlike typical 600V-class residential single-phase inverters, many current three-phase 10–20kW string inverters use higher-voltage DC platforms.
Depending on model:
Maximum PV Input Voltage: Approx. 1000–1100VDC
This allows longer PV strings and can reduce the number of parallel strings required in larger rooftop systems.
Current Sungrow 15–20kW products operate on a 1000V-class platform, with standby operation extending toward 1100V under specified conditions.
Multiple MPPT Design
Typical 10–20kW three-phase string inverters provide:
2 Independent MPPTs
depending on platform.
This allows PV arrays with two different orientations or string groups to operate independently.
Suitable roof configurations include:
- East / West Roofs
- Different Tilt Angles
- Separate Rooftop Areas
- Partially Shaded Arrays
- Different String Lengths
Selected platforms may use additional MPPT architectures, so the exact number must be confirmed according to model.
High-Current PV Module Compatibility
Modern commercial N-Type TOPCon modules can have high operating current.
Current 15–20kW three-phase products are available with approximately:
32A maximum PV operating current per MPPT
and approximately:
40A short-circuit current per MPPT
on representative two-string platforms.
Other inverter manufacturers may use different current limits.
Before connecting high-power solar modules, always verify:
- Module IMP
- Module ISC
- Strings per MPPT
- Inverter operating current limit
- Inverter short-circuit current limit
Reference Technical Specifications
Parameter |
Typical Specification |
Product Type |
Three-Phase Grid-Tied String Solar Inverter |
Rated AC Power |
10kW – 20kW |
Typical Power Options |
10 / 12 / 15 / 17 / 20kW |
Phase |
Three-Phase |
Maximum PV Input Voltage |
Typically Approx. 1000 – 1100VDC, Model Dependent |
MPPT Operating Voltage Range |
Approx. 150/160V – 950VDC, Model Dependent |
Start-Up Voltage |
Approx. 180 – 200VDC, Model Dependent |
Number of MPPTs |
Typically 2; Model Dependent |
Strings per MPPT |
Typically 1 – 2 |
PV Operating Current per MPPT |
Approx. 30 – 40A on Applicable Models |
PV Short-Circuit Current per MPPT |
Approx. 40 – 50A or Higher, Model Dependent |
Rated AC Voltage |
380V / 400V / 415V, Market Dependent |
Grid Frequency |
50Hz / 60Hz |
Grid Connection |
3L + N + PE on Applicable Models |
Maximum Efficiency |
Typically Approx. 98% – 98.5% |
Power Factor |
Adjustable |
THDi |
Typically <3% at Rated Power |
DC Oversizing |
Supported; Exact Ratio Model Dependent |
Communication |
RS485 / Wi-Fi / Ethernet / Bluetooth, Model Dependent |
Protection Rating |
Typically IP65 / IP66 |
Cooling |
Natural / Intelligent Cooling, Model Dependent |
Installation |
Indoor / Outdoor |
Mounting |
Wall-Mounted |
Operating Temperature |
Typically Approx. -25°C / -30°C to +60°C |
A current 15–20kW Sungrow reference platform uses two MPPTs, up to 32A per MPPT, 40A short-circuit current per MPPT and maximum efficiency around 98.3%.

Reference DC Input Parameters
Parameter |
Typical Reference |
Maximum PV Input Voltage |
Approx. 1000 – 1100VDC |
Minimum / Start-Up Voltage |
Approx. 150 – 200VDC |
MPPT Operating Range |
Approx. 150/160 – 950VDC |
Number of MPPTs |
Typically 2 |
Strings per MPPT |
Typically 1 – 2 |
Maximum PV Current |
Model Dependent |
Maximum Short-Circuit Current |
Model Dependent |
Final string length must be calculated according to the exact inverter and PV module.
Reference AC Output Parameters
Parameter |
Typical Specification |
Rated AC Power |
10kW – 20kW |
AC Phase |
Three-Phase |
Rated Voltage |
380V / 400V / 415V |
Connection |
3L + N + PE |
Frequency |
50Hz / 60Hz |
Power Factor |
Adjustable |
THDi |
Typically <3% |
Maximum Efficiency |
Approx. 98% – 98.5% |
For example, current representative 15kW, 17kW and 20kW products reach approximately 98.3% maximum efficiency.
PV Oversizing
Selected three-phase string inverters allow the installed PV array to exceed nominal inverter AC power.
This can improve annual inverter utilization and system energy yield.
The permitted DC oversizing ratio depends on:
- Inverter rated power
- Maximum recommended PV power
- MPPT current
- Maximum PV voltage
- Module orientation
- Local irradiation
- Grid requirements
The exact permitted DC/AC ratio should be taken from the selected inverter datasheet.
Solar Module Compatibility
The inverter is suitable for modern photovoltaic modules including:
- N-Type TOPCon Modules
- Monofacial Modules
- Bifacial Dual-Glass Modules
- 500W+ Solar Modules
- 600W+ Solar Modules on Compatible Models
A high module wattage does not automatically mean compatibility.
The following parameters must be checked:
- VOC
- VMP
- ISC
- IMP
- Maximum modules per string
- Number of strings per MPPT
- MPPT operating current
- MPPT short-circuit current
- Maximum inverter DC voltage
- Lowest site temperature
Export Limitation & Smart Meter
Selected models can work with a smart meter or CT to provide:
- Grid Export Monitoring
- Export Limitation
- Zero Export
- Load Consumption Monitoring
- Grid Import Monitoring
This is useful for C&I projects where export to the utility grid is restricted or controlled.
Smart Monitoring
Depending on model, available communication options may include:
- RS485
- Wi-Fi
- Ethernet
- Bluetooth
- Mobile APP
- Web Portal
- Cloud Monitoring Platform
Typical monitoring information includes:
- PV Power
- PV Voltage
- PV Current
- AC Power
- Grid Voltage
- Grid Frequency
- Daily Generation
- Monthly Generation
- Total Generation
- Fault Records
- Operating Status
Protection Functions
Depending on selected inverter model, protection functions may include:
- DC Reverse Polarity Protection
- AC Short-Circuit Protection
- Anti-Islanding Protection
- Residual Current Monitoring
- Insulation Resistance Monitoring
- Overvoltage Protection
- Overcurrent Protection
- Over-Temperature Protection
- DC Switch
- Type II DC Surge Protection
- Type II AC Surge Protection
- AFCI on Selected Models
- PID Recovery on Selected Models
- PV String Monitoring on Applicable Models
Current Sungrow 15–20kW products include Type II DC/AC surge protection, DC switch and AFCI capability in applicable configurations.
Typical System Configuration
A typical three-phase grid-connected solar system includes:
**Solar PV Modules
- Three-Phase Grid-Tied String Inverter
- Smart Meter / CT
- AC Distribution Panel
- Utility Grid
- Commercial / Residential Loads**
Optional equipment may include:
- Solar Mounting System
- DC Combiner / Protection
- AC Protection
- Monitoring Gateway
- Export Limitation Controller
Working Principle
During daylight hours:
PV Modules → DC Power → Three-Phase Inverter → AC Power
The generated electricity supplies onsite loads first.
When PV generation exceeds site consumption and grid export is permitted:
Surplus Solar Energy → Utility Grid
When solar generation is insufficient:
PV + Utility Grid → Loads
A normal grid-tied inverter is designed to disconnect during a utility outage for anti-islanding safety.
Therefore:
Grid-Tied String Inverter ≠ Backup Inverter
For battery energy storage or blackout backup, a compatible hybrid inverter and battery system should be selected.
Three-Phase C&I Advantages
Compared with a large single-phase system, a three-phase inverter can provide advantages for commercial applications including:
- Better integration with three-phase electrical systems
- Lower current per phase at the same total power
- Suitable operation with commercial equipment
- Easier connection to larger C&I distribution systems
- Higher PV system capacity
Final grid connection design must follow local utility requirements.
Applications
Typical applications include:
- Large Residential Properties
- Villas with Three-Phase Supply
- Commercial Buildings
- Offices
- Shops
- Factories
- Warehouses
- Workshops
- Farms
- Agricultural Facilities
- Schools
- Hotels
- Solar Carports
- Distributed C&I PV Systems
Environmental Specifications
Typical current products provide:
Protection Rating: IP65 / IP66
Operating Temperature: Approx. -25°C / -30°C to +60°C
Installation: Indoor / Outdoor
Mounting: Wall-Mounted
Cooling: Natural Cooling or Intelligent Cooling, Model Dependent
Exact environmental parameters depend on the selected inverter.
Certification & Compliance
Depending on inverter model and destination market, available standards and certifications may include:
- IEC / EN 62109-1
- IEC / EN 62109-2
- IEC 61727
- IEC 62116
- IEC / EN 61000 Series
- EN 50549
- VDE-AR-N 4105
- G98 / G99
- AS/NZS 4777.2
- CE Documentation
- Country-Specific Grid Certification
Representative current three-phase products list IEC/EN 62109, IEC 61727, IEC 62116, EN50549, G98/G99 and other regional standards depending on sales market.
Information Required for Quotation
Please provide:
- Required Inverter Power: 10 / 12 / 15 / 17 / 20kW
- Required Phase: Three-Phase
- Destination Country
- Grid Voltage
- Grid Frequency
- PV System Capacity
- Solar Module Wattage
- Module VOC
- Module VMP
- Module ISC
- Module IMP
- Required Number of MPPTs
- Whether Zero Export Is Required
- Required Communication Method
- Required Grid Certification
- Required Quantity
- Destination Port
- EXW / FOB / CIF Requirement
If the solar module has not yet been selected, project capacity and destination-country information can be provided for suitable module and inverter matching.
Packing & Shipping
The inverter is normally packed individually with protective carton and internal protective material.
Typical package contents may include:
- Grid-Tied Inverter
- Wall-Mounting Bracket
- PV Connectors
- AC Connector
- Communication Accessories
- Installation Hardware
- User Manual
Exact net weight, gross weight and packaging dimensions depend on the selected model.
Trade Terms
EXW / FOB / CIF
Please contact us for:
- Current Stock
- Latest Price
- Available Brands
- Exact Model Numbers
- Official Datasheets
- Certification Documents
- Packing Information
- Container Loading Details
- Shipping Quotation
Chudu Metal
Solar PV Modules, Solar Inverters, Energy Storage Batteries & Solar Mounting System Supplier from China
🌐 Website: www.chudufastener.com
📧 Email: han@hbchudu.com
📱 WhatsApp / Phone: +86 19333039217
description2
Contact Us
- barry@hbchudu.com
- +86 18533933520
-
Hebei Chudu Metal Products Co., Ltd.
Our experts will solve them in no time.


Phone
Facebook
Youtube