Leave Your Message
100kWh–215kWh High-Voltage C&I LFP Battery Cabinet
C&I Energy Storage & BESS

100kWh–215kWh High-Voltage C&I LFP Battery Cabinet

Chudu Metal 100kWh–215kWh High-Voltage LFP Battery Cabinet for Commercial & Industrial Energy Storage Systems

    185c5df3-3f21-4e3b-bb77-2e71ee0aa8f6
    18b5808c-6ce9-4629-b532-0e07ee3c8f85
    e3a21be9-2f95-4450-bf67-c179250ee9a8

    Product Overview


    Chudu Metal 100kWh–215kWh High-Voltage LFP Battery Cabinets are designed for commercial and industrial energy storage applications, including factories, warehouses, commercial buildings, photovoltaic energy storage projects, microgrids and backup power systems.

    The battery cabinet adopts Lithium Iron Phosphate (LiFePO4 / LFP) battery technology and a high-voltage DC architecture, providing high energy density, long cycle life and reliable performance for commercial and industrial energy storage applications.

    Typical cabinet capacities include 100kWh, 140kWh and 215kWh, with different battery cell capacities, system voltages and charge/discharge capabilities available according to project requirements.

    The cabinet integrates battery modules, a Battery Management System (BMS), DC protection, thermal management, fire-protection components and communication equipment into a floor-mounted enclosure.

    The battery cabinet is primarily a DC-side energy storage unit and can be connected to a compatible external PCS, hybrid inverter or other power conversion equipment.

    PCS, EMS, STS and MPPT equipment are not assumed to be integrated unless specifically stated in the selected configuration.

    Available Energy Capacity


    Typical nominal energy configurations include:

    100kWh / 140kWh / 215kWh

    Actual nominal energy, usable energy, cell capacity, system voltage, dimensions and weight depend on the selected configuration.

    Current commercial outdoor battery cabinets in this category include approximately 100kWh, 140kWh and 215kWh configurations.

    Main Features


    High-Voltage DC Battery Architecture

    Multiple battery packs are connected in series to form a high-voltage DC energy storage system.

    Depending on system capacity and battery configuration, nominal voltage can range from approximately:

    320VDC to 768VDC

    Representative operating voltage ranges can extend from approximately:

    290VDC to 864VDC

    depending on the selected model.

    This high-voltage architecture is suitable for commercial and industrial energy storage systems requiring higher charge and discharge power.

    Lithium Iron Phosphate Battery Technology

    The battery cabinet uses Lithium Iron Phosphate (LiFePO4 / LFP) cells.

    Key characteristics include:

    • High thermal stability
    • Long cycle life
    • Stable charge and discharge performance
    • High safety characteristics
    • Low maintenance requirements
    • Suitability for frequent daily energy cycling

    Integrated Battery Management System

    The integrated Battery Management System (BMS) manages battery operation and system protection.

    Depending on configuration, monitored parameters and functions may include:

    • Individual cell voltage
    • Battery pack voltage
    • Total system voltage
    • Charge and discharge current
    • Cell temperature
    • Cabinet temperature
    • State of Charge (SoC)
    • State of Health (SoH)
    • Cell balancing
    • Overvoltage protection
    • Undervoltage protection
    • Charge overcurrent protection
    • Discharge overcurrent protection
    • Short-circuit protection
    • Over-temperature protection
    • Low-temperature protection
    • Communication monitoring
    • Fault and alarm management

    High Depth of Discharge

    Selected battery cabinet configurations support:

    Up to approximately 95% Depth of Discharge (DoD)

    The final recommended DoD depends on battery cell type, BMS configuration and warranty conditions.

    Long Cycle Life

    Selected C&I LFP battery cabinets can provide:

    8,000+ cycles

    under specified operating and test conditions.

    Actual cycle life depends on Depth of Discharge, temperature, charge/discharge rate, operating conditions and BMS strategy.

    For example, current Dyness BF100 and BF200 systems specify 28,000 cycles under their stated test conditions.

    Modular Battery Pack Design

    The cabinet contains multiple series-connected battery packs.

    The modular structure allows battery packs and system components to be organized inside a centralized cabinet, helping simplify installation, maintenance and system expansion.

    Battery pack quantity and internal electrical configuration depend on the selected cabinet capacity.

    Outdoor Cabinet Design

    Selected models are designed for outdoor installation and can provide an enclosure protection rating of:

    IP55

    This makes the cabinet suitable for commercial and industrial outdoor installations when installed according to the applicable installation requirements.

    Current Dyness BF100 and BF200 outdoor cabinets are specified with IP55 enclosure protection.

    Air-Cooled Thermal Management

    The battery cabinet uses an intelligent air-cooled thermal management system to maintain suitable battery operating temperatures.

    Depending on the selected model, the thermal management system may include:

    • Air-conditioning cooling
    • Electric heating
    • Intelligent fan control
    • Cell temperature monitoring
    • Cabinet temperature monitoring
    • High-temperature protection
    • Low-temperature protection

    Representative systems currently use approximately 2kW–5kW cooling capacity, depending on cabinet size and battery capacity.

    Multi-Level Fire Protection

    Depending on cabinet configuration, safety systems may include:

    • Multi-sensor detection
    • Smoke and temperature monitoring
    • Aerosol fire suppression
    • Water-based fire protection interface or system
    • Audible and visual alarm
    • Explosion-proof ventilation
    • Water ingress monitoring
    • Emergency shutdown

    Actual fire-protection configuration depends on the supplied battery cabinet and destination-market requirements.

    Intelligent Communication

    Depending on system configuration, communication interfaces may include:

    Ethernet / RS485 / 4G

    Selected models may additionally support Bluetooth or other communication interfaces.

    The battery cabinet can communicate with compatible PCS, EMS and monitoring systems.

    Technical Specifications


    Parameter

    Specification

    Product Type

    High-Voltage C&I LFP Battery Cabinet

    Battery Chemistry

    Lithium Iron Phosphate (LiFePO4 / LFP)

    Nominal Energy Capacity

    Approx. 100kWh – 215kWh

    Typical Energy Options

    100kWh / 140kWh / 215kWh

    Battery Cell Capacity

    Typically 280Ah / 314Ah, Depending on Model

    System Architecture

    High-Voltage DC Battery Cabinet

    Nominal System Voltage

    Approx. 320VDC – 768VDC, Depending on Configuration

    Operating Voltage Range

    Approx. 290VDC – 864VDC, Depending on Configuration

    Rated Current

    Approx. 140A – 157A, Model Dependent

    Maximum Current

    Approx. 160A – 180A, Model Dependent

    Recommended Depth of Discharge

    Up to Approx. 95%, Model Dependent

    Cycle Life

    Up to 8,000+ Cycles on Selected Models under Specified Conditions

    Battery Management System

    Integrated BMS

    State of Charge Monitoring

    Supported

    State of Health Monitoring

    Available on Applicable Systems

    Cell Balancing

    Supported by BMS

    Thermal Management

    Intelligent Air Cooling / Air Conditioning

    Cooling Capacity

    Approx. 2kW – 5kW on Representative Models

    Heating Function

    Available on Applicable Models

    Protection Rating

    Typically IP55 for Outdoor Cabinet Models

    Anti-Corrosion Grade

    Typically C3 / C4; Higher Grades Available on Selected Models

    Operating Temperature

    Typically Approx. -20°C to 50°C

    Temperature Derating

    Typically Above Approx. 45°C

    Operating Humidity

    Typically 0 – 95% RH, Non-Condensing

    Maximum Installation Altitude

    Up to Approx. 3000m on Selected Models

    Altitude Derating

    Typically Above Approx. 2000m

    Communication

    Ethernet / RS485 / 4G; Bluetooth on Selected Models

    Fire Protection

    Multi-Sensor Detection / Aerosol / Water Fire Protection / Alarm / Explosion-Proof Ventilation, Model Dependent

    Cooling Method

    Air-Cooled

    Noise Level

    Typically ≤65 – 75dB, Model Dependent

    Installation

    Outdoor Floor-Mounted Cabinet

    PCS

    External Unless Integrated Configuration Is Specified

    EMS

    External / Optional Depending on Project Configuration

    Application

    Commercial & Industrial Energy Storage

    Warranty

    According to Selected Model and Warranty Conditions

    Note: Final nominal energy, usable energy, cell capacity, voltage range, rated current, maximum current, cabinet dimensions, cabinet weight, cooling capacity, fire-protection configuration and communication interfaces shall be confirmed according to the selected battery cabinet model.

    Reference Battery Cabinet Configurations


    Parameter 100kWh Configuration 140kWh Configuration 215kWh Configuration
    Nominal Energy Approx. 100kWh Approx. 140kWh Approx. 215kWh
    Cell Capacity Approx. 314Ah Approx. 314Ah Approx. 280Ah
    Nominal Voltage Approx. 320VDC Approx. 448VDC Approx. 768VDC
    Operating Voltage Range Approx. 290 – 360VDC Approx. 406 – 504VDC Approx. 696 – 864VDC
    Rated Current Approx. 157A Approx. 157A Approx. 140A
    Maximum Current Approx. 180A Approx. 180A Approx. 160A
    Cooling Air Cooling Air Cooling Air Cooling
    Protection Rating IP55 IP55 IP55
    Typical Dimensions (W×D×H) 850×1320×2350mm 850×1320×2350mm 1320×1190×2250mm
    Typical Weight Approx. 1360kg Approx. 1650kg Approx. 2500kg

    The 100kWh and 140kWh reference configurations are based on current Dyness BF100-C140 specifications, while the 215kWh configuration is based on the current BF200 outdoor DC battery cabinet architecture.

    Working Principle


    The high-voltage battery cabinet stores electrical energy generated by a photovoltaic system or supplied from the utility grid through compatible power conversion equipment.

    During charging, a compatible PCS or hybrid inverter converts and manages electrical energy and charges the battery according to BMS and EMS control commands.

    During discharge, the battery cabinet supplies high-voltage DC energy to the PCS or compatible inverter, which converts the energy into AC electricity for commercial and industrial loads.

    Depending on project configuration, the system can support energy management strategies such as:

    • PV self-consumption
    • Peak shaving
    • Valley charging and peak discharging
    • Time-of-use energy management
    • Backup power
    • Demand management
    • Microgrid operation
    • Grid support where permitted

    Applications

    The battery cabinet is suitable for:

    • Factory energy storage
    • Warehouse energy storage
    • Commercial buildings
    • Industrial facilities
    • Logistics centers
    • Shopping centers
    • Office buildings
    • Agricultural facilities
    • PV + Energy Storage projects
    • Peak-shaving systems
    • Backup power systems
    • Microgrids
    • EV charging stations
    • Distributed commercial solar projects
    6e0e5cf7-4917-4937-a48f-378809

    Typical C&I Energy Storage System Configuration


    A typical C&I energy storage system based on a high-voltage battery cabinet can include:

    **Solar PV Modules

    • PV Inverter / MPPT Equipment
    • High-Voltage LFP Battery Cabinet
    • PCS
    • EMS
    • STS, if required
    • AC Distribution Equipment
    • Smart Meter / CT
    • Utility Grid
    • Commercial or Industrial Loads**

    A generator can also be integrated in compatible backup or microgrid systems.

    Battery Cabinet vs. All-in-One C&I ESS


    High-Voltage Battery Cabinet

    A battery cabinet primarily integrates:

    • LFP battery cells
    • Battery modules or packs
    • BMS
    • DC protection
    • Thermal management
    • Fire protection
    • Communication equipment
    • Outdoor enclosure

    A compatible external PCS or hybrid inverter is generally required for DC-to-AC power conversion.

    All-in-One C&I Energy Storage System


    An all-in-one C&I ESS may additionally integrate:

    • PCS
    • EMS
    • MPPT
    • STS
    • AC/DC distribution
    • Other power conversion and energy management equipment

    Therefore, this product is defined as a High-Voltage C&I Battery Cabinet, not automatically as an All-in-One C&I ESS.

    Safety & Protection


    Depending on the selected configuration, protection functions may include:

    • Cell overvoltage protection
    • Cell undervoltage protection
    • Pack overvoltage protection
    • Pack undervoltage protection
    • Charge overcurrent protection
    • Discharge overcurrent protection
    • Short-circuit protection
    • Over-temperature protection
    • Low-temperature protection
    • Insulation monitoring
    • Smoke and temperature detection
    • Fire suppression
    • Audible and visual alarm
    • Emergency shutdown
    • Explosion-proof ventilation
    • Water ingress monitoring
    • Communication fault protection

    Monitoring & Communication


    Depending on BMS and EMS configuration, available monitoring information may include:

    • State of Charge
    • State of Health
    • Cell voltage
    • Battery pack voltage
    • Total system voltage
    • Battery current
    • Charge power
    • Discharge power
    • Cell temperature
    • Cabinet temperature
    • Thermal management status
    • Fire-protection status
    • Alarm information
    • Fault history
    • Energy throughput
    • Historical operating data

    Communication can be provided through:

    Ethernet / RS485 / 4G

    with additional interfaces available on selected configurations.

    Environmental Requirements


    Typical outdoor C&I battery cabinet operating conditions include:

    Operating Temperature: approximately -20°C to 50°C
    Operating Humidity: approximately 0–95% RH, non-condensing
    Protection Rating: typically IP55
    Maximum Installation Altitude: up to approximately 3000m on selected models

    Output or operating derating may apply above approximately 45°C ambient temperature or above approximately 2000m altitude.

    Compliance, Safety & Transport Documentation


    Depending on the selected battery cabinet and destination market, applicable certificates and documents may include:

    CE
    LVD
    IEC 62619, where applicable
    UN38.3
    SDS (Safety Data Sheet)
    Other Applicable Regional Battery Safety Requirements

    Actual certification packages vary by battery model and destination market and must be confirmed before quotation.

    UN38.3 is lithium-battery transport testing/documentation, while SDS is safety documentation and should not simply be described as a product certification.

    Information Required for Quotation


    To recommend a suitable C&I battery cabinet configuration, please provide:

    1. Required energy storage capacity
    2. Required charge/discharge power
    3. PCS or hybrid inverter brand and model
    4. PCS DC operating voltage range
    5. Maximum PCS charge/discharge current
    6. Solar PV system capacity
    7. Daily electricity consumption
    8. Peak electrical load
    9. Required backup duration
    10. Local grid voltage
    11. Required number of battery cabinets
    12. Installation environment
    13. Ambient temperature range
    14. Installation altitude
    15. Installation country
    16. Required certifications
    17. Whether EMS is required
    18. Whether STS / backup switching is required
    19. Required fire-protection configuration

    Packing & Shipping


    Commercial and industrial battery cabinets require professional lithium-battery transportation arrangements.

    Depending on the battery configuration, transportation mode and destination country, applicable documents may include:

    UN38.3 Test Documentation
    SDS
    Dangerous Goods Declaration
    Other Required Lithium-Battery Transport Documents

    Because C&I battery cabinets are heavy equipment, transportation planning may also require forklift handling, lifting points, reinforced export packaging, container loading planning and destination unloading arrangements.

    Chudu Metal

    Solar PV Modules, Solar Mounting Components & Solar Product Supplier from China
    🌐 Website:  www.chudufastener.com
    📧 Email:  han@hbchudu.com
    📱 WhatsApp / Phone: +86 19333039217

    description2

    Contact Us

    Our experts will solve them in no time.