100kW/215kWh All-in-One Liquid-Cooled Commercial & Industrial Energy Storage System



Product Overview
Chudu Metal 100kW/215kWh All-in-One Liquid-Cooled C&I Battery Energy Storage System is designed for commercial and industrial energy storage applications, including factories, warehouses, industrial parks, commercial buildings, photovoltaic energy storage projects, EV charging stations and microgrids.
The system combines a high-voltage Lithium Iron Phosphate (LiFePO4 / LFP) battery system, Battery Management System (BMS), Power Conversion System (PCS), power distribution, intelligent system control, liquid-cooled battery thermal management and multi-level safety protection in an integrated outdoor cabinet.
With approximately 215kWh of battery energy capacity and 100kW of rated AC charge/discharge power, the system is suitable for peak shaving, load shifting, photovoltaic self-consumption, time-of-use energy management, demand management and backup applications where supported by the selected PCS and switching configuration.
Current mainstream 100kW/215kWh C&I systems use this type of integrated high-voltage architecture.
Main Features
100kW / 215kWh Integrated C&I Energy Storage Architecture
The system provides approximately:
Rated AC Power: 100kW
Battery Energy: 215kWh
A typical all-in-one configuration can include:
- LiFePO4 battery packs
- Battery Management System (BMS)
- Power Conversion System (PCS)
- High-voltage DC protection
- AC power distribution
- Liquid cooling system
- Fire detection and suppression system
- Local system controller
- EMS or EMS communication interface
- Remote monitoring and communication
The exact EMS architecture depends on the selected system configuration. Some current C&I systems integrate PCS, BMS and EMS, while others use an optional or system-level EMS controller.
LiFePO4 Battery Technology
The system adopts Lithium Iron Phosphate (LiFePO4 / LFP) battery chemistry.
A representative configuration uses:
Cell Voltage: 3.2V
Cell Capacity: 280Ah
Battery Configuration: 1P240S
Nominal Energy: approximately 215kWh
Nominal Battery Voltage: approximately 768VDC
This 280Ah / 1P240S / 768V architecture is currently used in commercial 100kW/215kWh ESS products.
High-Voltage Battery System
The battery system operates on a high-voltage DC platform.
A representative standard configuration provides:
Nominal Voltage: 768VDC
Operating Voltage Range: approximately 672–876VDC
Actual operating voltage range may vary according to battery cell limits, BMS settings and PCS configuration.
For example, current 215kWh products specify ranges including 672–876VDC, 649–876VDC and 660–864VDC.
Integrated 100kW PCS
The integrated bidirectional Power Conversion System (PCS) manages AC/DC power conversion between the battery system and the utility/load side.
Typical functions include:
- Battery charging
- Battery discharging
- AC-to-DC conversion
- DC-to-AC conversion
- Grid-connected operation
- Active and reactive power control
- Power-factor control
- Energy dispatch according to EMS commands
Off-grid or backup operation requires a PCS with grid-forming capability and suitable transfer/switching equipment and should not be assumed for every configuration.
Liquid-Cooled Battery Thermal Management
The battery side uses intelligent liquid cooling to maintain suitable cell operating temperatures and improve temperature uniformity across battery packs.
The liquid-cooling system can include:
- Liquid cooling plates
- Coolant circulation loop
- Pump
- Heat exchanger / chiller
- Temperature sensors
- Thermal management controller
Current liquid-cooled C&I systems use this architecture to reduce battery-cell temperature differences and improve thermal consistency.
Note: The battery system is liquid-cooled. The PCS may use independent smart air cooling depending on system design.
Battery Management System
The integrated Battery Management System (BMS) can monitor and manage:
- Cell voltage
- Battery pack voltage
- Total battery voltage
- Charge current
- Discharge current
- Cell temperature
- State of Charge (SoC)
- State of Health (SoH), where supported
- Cell balancing
- Insulation status
- Alarm status
- Battery protection status
Typical protection functions include:
- Overvoltage protection
- Undervoltage protection
- Overcurrent protection
- Short-circuit protection
- Over-temperature protection
- Low-temperature protection
- Insulation fault protection
- Communication fault protection
Energy Management
Depending on the selected configuration, EMS functions may be integrated into the cabinet or provided by an external/system-level controller.
Typical functions include:
- Peak shaving
- Load shifting
- Time-of-use optimization
- PV self-consumption
- Demand management
- Charge/discharge scheduling
- Remote monitoring
- Multi-cabinet coordination
- Energy statistics
- Alarm and operating-data management
High Depth of Discharge
Selected systems support:
Up to approximately 95% Depth of Discharge (DoD)
Final DoD depends on cell chemistry, BMS strategy and warranty conditions. Current 100kW/215kWh 280Ah systems are available with up to 95% DoD.
Modular Expansion
Multiple 100kW/215kWh cabinets can be connected to create larger systems.
Typical nominal configurations include:
Cabinet Quantity |
System Power |
Nominal Energy |
1 |
100kW |
215kWh |
2 |
200kW |
430kWh |
3 |
300kW |
645kWh |
4 |
400kW |
860kWh |
5 |
500kW |
1.075MWh |
Current modular C&I systems use this same cabinet-expansion concept.
Technical Specifications
Parameter |
Specification |
Product Type |
All-in-One Liquid-Cooled C&I Battery Energy Storage System |
Rated AC Power |
100kW |
Nominal Battery Energy |
Approx. 215kWh |
Battery Chemistry |
Lithium Iron Phosphate (LiFePO4 / LFP) |
Typical Cell Specification |
3.2V / 280Ah |
Typical Battery Configuration |
1P240S |
Nominal Battery Voltage |
Approx. 768VDC |
Battery Operating Voltage |
Approx. 672 – 876VDC, Reference Configuration |
Charge / Discharge Rate |
Typically ≤0.5C |
Recommended Depth of Discharge |
Up to Approx. 95%, Model Dependent |
Rated Grid Voltage |
380VAC / 400VAC, Market and Model Dependent |
Rated Grid Frequency |
50Hz / 60Hz |
Grid Connection |
Three-Phase; 3L+N+PE on Applicable Models |
AC Current THD |
Typically ≤3% at Rated Operation on Applicable Models |
System Round-Trip Efficiency |
Typically Approx. 88% – 90%+, System Dependent |
Battery Management System |
Integrated BMS |
Power Conversion System |
Integrated Bidirectional PCS |
Energy Management |
Integrated or System-Level EMS, Depending on Configuration |
Battery Thermal Management |
Intelligent Liquid Cooling |
PCS Cooling |
Air Cooling / Model Dependent |
Fire Detection |
Temperature / Smoke / Other Sensors, Configuration Dependent |
Fire Suppression |
Aerosol / Gas / Water-Based System, Configuration Dependent |
Enclosure Protection |
Typically IP54 / IP55 |
Operating Temperature |
Typically Approx. -20°C to 55°C |
Temperature Derating |
Typically Above Approx. 45°C |
Operating Humidity |
Typically 0 – 95% RH, Non-Condensing |
Installation Altitude |
Typically Up to Approx. 3000m; Higher Altitude Available on Selected Models with Derating |
Communication |
Ethernet; 4G / RS485 / Other Interfaces on Selected Models |
Cycle Life |
≥6,000 Cycles on Applicable Models under Specified Conditions |
Installation |
Outdoor Floor-Mounted Cabinet |
Expansion |
Multi-Cabinet Parallel Operation Supported |
Application |
Commercial & Industrial Energy Storage |
The principal reference values above are consistent with current 100kW/215kWh systems from Deye, Sungrow and Billion; enclosure, RTE, communication and environmental limits vary by model.
Note: Final voltage range, dimensions, weight, cycle life, communication interfaces, fire-protection configuration, enclosure rating and certification package shall be confirmed according to the selected production model.
Reference Battery Parameters
Parameter |
Reference Specification |
Battery Chemistry |
LiFePO4 / LFP |
Cell Specification |
3.2V / 280Ah |
System Configuration |
1P240S |
Nominal Energy |
Approx. 215.04kWh |
Nominal Voltage |
Approx. 768VDC |
Operating Voltage |
Approx. 672 – 876VDC |
Charge / Discharge Rate |
≤0.5C |
DoD |
Up to Approx. 95% |
Thermal Management |
Liquid Cooling |
The 215.04kWh nominal value results from the representative 3.2V × 280Ah × 240-cell series configuration used by current systems.
Reference AC Parameters
Parameter |
Reference Specification |
Rated AC Power |
100kW |
Rated Grid Voltage |
380VAC / 400VAC |
Rated Frequency |
50Hz / 60Hz |
Grid Type |
Three-Phase |
Wiring |
3L+N+PE on Applicable Models |
THDi |
Typically ≤3% at Rated Power on Applicable Models |
Current products use both 380V and 400V three-phase configurations depending on market.

Working Principle
The system can store electrical energy from a photovoltaic system or the utility grid.
When solar generation exceeds site consumption, or when electricity prices are low, the battery can be charged through the integrated PCS.
When electricity demand increases or electricity prices are higher, stored battery energy can be converted by the PCS and supplied to commercial or industrial loads.
The EMS or system controller can manage battery charging and discharging according to:
- PV generation
- Site load
- Battery State of Charge
- Electricity tariffs
- Demand limits
- User-defined energy strategies
- Grid conditions
Typical Operating Modes
PV Self-Consumption
Excess photovoltaic energy is stored in the battery for later use, increasing onsite utilization of solar energy.
Peak Shaving
The battery discharges when facility demand approaches a preset limit, helping reduce peak grid demand.
Time-of-Use Energy Management
The battery can charge during lower-price periods and discharge during higher-price periods according to electricity tariff settings.
Load Shifting
Electrical energy can be moved from periods of lower demand or lower electricity cost to periods of higher demand.
Backup Power
Backup power operation can be supported when the selected system includes appropriate grid-forming PCS functionality, protection and transfer equipment.
Microgrid Operation
Compatible systems can be integrated with:
Solar PV + Utility Grid + Energy Storage + Generator + Loads
according to project requirements.
Applications
The system is suitable for:
- Manufacturing plants
- Factories
- Warehouses
- Industrial parks
- Commercial buildings
- Shopping centers
- Office buildings
- Hotels
- Agricultural facilities
- Logistics centers
- EV charging stations
- PV + Energy Storage projects
- Microgrids
- Peak-shaving projects
- Demand-management projects
- Backup power applications
Typical C&I Energy Storage System
A typical installation can include:
**Solar PV Modules
- PV Inverter
+ 100kW/215kWh All-in-One C&I ESS - EMS / System Controller
- Smart Meter / CT
- Utility Grid
- AC Distribution
- Commercial or Industrial Loads**
For backup applications, an STS or other approved transfer device may be required depending on system architecture.
All-in-One C&I ESS vs. High-Voltage Battery Cabinet
High-Voltage Battery Cabinet
A standalone high-voltage battery cabinet mainly contains:
- Battery cells and packs
- BMS
- DC protection
- Battery thermal management
- Fire protection
- Communication equipment
It generally requires an external PCS for AC/DC conversion.
All-in-One C&I BESS
An all-in-one C&I energy storage system integrates more system-level equipment, typically including:
- Battery system
- BMS
- PCS
- Power distribution
- Liquid cooling
- Fire detection and suppression
- System control
- EMS or EMS interface
This reduces onsite integration work compared with a standalone DC battery cabinet.
Safety & Protection
Depending on configuration, protection functions may include:
- Cell overvoltage protection
- Cell undervoltage protection
- Battery overcurrent protection
- Short-circuit protection
- Over-temperature protection
- Low-temperature protection
- Insulation monitoring
- Smoke detection
- Temperature detection
- Pressure monitoring
- Fire suppression
- Audible and visual alarm
- Emergency stop
- AC-side protection
- DC-side protection
- Communication fault protection
Fire Detection & Suppression
Depending on model and destination-market requirements, the system can use combinations of:
- Smoke detection
- Temperature detection
- Pressure monitoring
- Aerosol fire suppression
- Gas-based suppression
- Water-based fire protection
- Audible and visual alarm
- Emergency shutdown
Sungrow and Billian's current systems demonstrate multi-sensor detection and system-level fire suppression architectures, but the exact method differs between products.
Monitoring & Communication
Depending on system configuration, monitoring parameters can include:
- State of Charge
- State of Health
- Cell voltage
- Battery voltage
- Battery current
- Charge/discharge power
- Cell temperature
- Battery thermal-management status
- PCS operating status
- Grid voltage
- Grid frequency
- Alarm information
- Fire-protection status
- Energy throughput
- Historical operating data
Typical communication options include:
Ethernet / Modbus TCP / RS485 / 4G
depending on the selected controller and system configuration.
Environmental Requirements
Typical outdoor operating conditions include:
Operating Temperature: approximately -20°C to 55°C
Operating Humidity: approximately 0–95% RH, non-condensing
Protection Rating: typically IP54 / IP55
Installation: outdoor floor-mounted
Maximum Altitude: typically approximately 3000m, with selected systems supporting higher altitude subject to derating
Representative products currently range from IP54 to IP55 and approximately 3000–4000m maximum installation altitude.
Compliance, Safety & Transport Documentation
Depending on the selected model and destination market, applicable standards and documents may include:
- IEC 62619
- IEC / EN 62477-1
- IEC 61000 series
- CE requirements, where applicable
- UL 1973, where applicable
- UL 9540A test documentation, where applicable
- UN38.3
- SDS
- Local grid-connection requirements
Current mainstream systems reference IEC 62619 for battery safety, IEC 62477 for power-conversion equipment, IEC 61000 EMC requirements and UN38.3 for lithium-battery transport.
UN38.3 is lithium-battery transport testing/documentation. SDS is safety documentation. UL 9540A is a thermal-runaway fire-propagation test method and should not be presented simply as a universal product certification.
Information Required for Quotation
For accurate system selection and quotation, please provide:
- Required energy storage capacity
- Required charge/discharge power
- Daily electricity consumption
- Maximum site load
- Existing or planned solar PV capacity
- Local grid voltage and frequency
- Peak and off-peak electricity tariff periods
- Required backup duration
- Whether backup or off-grid operation is required
- Whether generator integration is required
- Required number of ESS cabinets
- Installation environment
- Ambient temperature range
- Installation altitude
- Destination country
- Required certifications
- Local grid-connection requirements
- Fire-protection requirements
Packing & Shipping
The 100kW/215kWh C&I BESS is heavy lithium-battery equipment and requires professional export and transportation planning.
Depending on the final configuration and destination, applicable documents may include:
- UN38.3 test documentation
- SDS
- Dangerous Goods Declaration
- Lithium battery transport documentation
- Other destination-specific shipping documents
Forklift handling, lifting requirements, reinforced export packaging, container loading and destination unloading arrangements should be confirmed before shipment.
Chudu Metal
Solar PV Modules, Solar Mounting Components & Solar Product Supplier from China
🌐 Website: www.chudufastener.com
📧 Email: han@hbchudu.com
📱 WhatsApp / Phone: +86 19333039217
description2
Contact Us
- barry@hbchudu.com
- +86 18533933520
-
Hebei Chudu Metal Products Co., Ltd.
Our experts will solve them in no time.


Phone
Facebook
Youtube